SCALE CALIBRATION PROCEDURE
1 Nothing should be hanging from the hanger/spreader assembly except the sling hangers During the
time the lift is turned ON and the battery level is displayed, the microprocessor is resetting Zero.
2. Press the “ON/OFF” key to power up the unit.
3 Pick up an exact and known weight (preferably 200 lb.). (Note: Once in the calibration menu, the
lift is no longer able to move.)
4. Press the “WEIGHT” key to ensure the scale is functional.
5. Enter the calibration menu. After power up sequence, press and hold the “DOWN” key followed
quickly by the “UP” key and hold both keys for 5 seconds.
6. Press the “UP” key to calibration menu. Press Enter (right toggle) twice.
7. Scroll to the proper calibration weight and enter selection. (Note: If sling is not attached, subtract
1.5 lb.)
8 “Begin weight calibration” is displayed. Press Enter (right toggle), select Yes, and press Enter (right
toggle) to execute calibration. Display shows “CALIBRATING”.
9. When the display leaves this menu selection, it will have been calibrated to the selected weight. Exit
the calibration menu.
10. Press “WEIGHT” key to verify calibrated weight to 1% accuracy. Calibration is now complete.