Chapter 3
Connecting the Switch to the Network
3 - 8
Entering the Private Subnet
Enter the private subnet and VLAN of the failed switch, as well as the
VLAN for the private metalog subnet. The VLANs must be unique in the
network, shared only among the ARX devices in the RON. The defaults
(1002 and 1003) may be sufficient for the installation. See the following
example.
...
The
switch's
internal
subnet
requires
an
IP
address
and
mask.
7.
Enter
the
switch's
private
IP
address
in
the
format
nnn.nnn.nnn.nnn.(default=169.254.151.64)
#
169.254.245.128
8.
Enter
the
switch's
private
subnet
mask
in
the
format
nnn.nnn.nnn.nnn.(default=255.255.255.192)
#
<Enter>
The
private
subnet
VLAN
is
used
externally
for
redundancy
traffic.
Be
sure
this
value
does
not
conflict
with
existing
VLAN
IDs.
9.
Enter
the
switch's
private
subnet
VLAN
in
the
format
integer
[1
‐
4095].(default=1002)
#
1006
<Enter>
The
private
subnet
metalog
VLAN
is
used
for
storing
file
‐
change
logs
on
battery
‐
backed
NVRAM,
possibly
on
a
redundant
peer.
Be
sure
this
value
does
not
conflict
with
existing
VLAN
IDs.
10.
Enter
the
switch's
private
subnet
metalog
VLAN
in
the
format
integer
[1
‐
4095].(default=1003)
#
1006
<Enter>
Finding the UUID of the Failed Switch
When a switch imports storage from backend file servers, it marks each
share with its UUID (Universally-Unique ID). A replacement switch must
use the same UUID or it will reject all shares imported by its predecessor.
Also, you must set the UUID if the switch is brought back to its factory
defaults. A
Manufacturing Installation
by F5 personnel resets the switch
and its UUID.
The UUID appears at the top of the output of a
show running-config
command as in the following example from a switch named
bstnA
. The
UUID is highlighted in bold.
;
ARX
‐
500
;
Version
6.00.000.12538
(Feb
16
2010
20:14:13)
[nbuilds]
;
Database
version:
600000.21
;
Generated
running
‐
config
Mon
Feb
22
03:06:35
2011
;
System
UUID
db922942
‐
876f
‐
11d8
‐
9110
‐
8dtu78fc8329
;
ip
private
vlan
internal
1006
metalog
1007
subnet
169.254.245.128
255.255.255.192
;
terminal
character
‐
set
unicode
‐
utf
‐
8
config
vlan
103
...
Summary of Contents for ARX-500
Page 1: ...ARX 500 Hardware Installation Guide 810 0039 00 ...
Page 2: ......
Page 7: ...Table of Contents ...
Page 8: ......
Page 10: ...Table of Contents x ...
Page 11: ......
Page 12: ...Table of Contents xii ...
Page 14: ......
Page 22: ......
Page 32: ......
Page 50: ...Chapter 3 Connecting the Switch to the Network 3 20 ...
Page 51: ...4 Maintenance Powering Down the ARX 500 POST Diagnostics Front Panel LEDs Rear Panel LEDs ...
Page 52: ......
Page 59: ...Index ...
Page 60: ......
Page 62: ...Index Index 4 ...