Powering Down the ARX-500
ARX-500 Hardware Installation Guide
4 - 3
Powering Down the ARX-500
You can power down the ARX-500 with the CLI command
shutdown
. This
command causes power to be cut from all systems except the Non-Volatile
RAM (NVRAM), which contains namespace metadata information that
managed volumes are currently using. Once the NVRAM loses power from
an external source, it uses a battery backup for up to 72 hours.
For details on powering down a single ARX and a redundant pair, consult
the
ARX CLI Maintenance Guide
,
Powering Down the ARX
.
This procedure prepares the ARX pair for a planned power outage.
For power outages of greater than 72 hours, contact F5 Support.
POST Diagnostics
When the device reboots and the system powers up, POST (power-on
self-test) diagnostics run to verify basic hardware integrity. You can view
any hardware failures at the system console through the
show version
and
show chassis
commands.
The following sample shows the output from the
show version
command.
provA(cfg)#
show
version
Copyright
(c)
2002
‐
2012
by
F5
Networks,
Inc.
All
rights
reserved.
Running
Release
test3.rel
:
Version
6.02.000.14365
(May
2
2012
20:08:52)
[nbuilds]
Armed
Release
test3.rel
:
Version
6.02.000.14365
(May
2
2012
20:08:52)
[nbuilds]
Backup
Release
test2.rel
:
Version
6.02.000.14365
(May
2
2012
20:08:52)
[nbuilds]
System
Configuration:
Version
602000.33
provA
uptime
is
0
weeks,
0
days,
2
hours,
35
minutes.
Slot
Admin
ModuleType
ModuleState
FW
Upgrade
‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
1
Enabled
ACM
Online
Disabled
Resource
State
Forwarding
‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
Switch
Up
Disabled
The following sample shows output from the
show chassis
command.
provA#
show
chassis
Summary of Contents for ARX-500
Page 1: ...ARX 500 Hardware Installation Guide 810 0039 00 ...
Page 2: ......
Page 7: ...Table of Contents ...
Page 8: ......
Page 10: ...Table of Contents x ...
Page 11: ......
Page 12: ...Table of Contents xii ...
Page 14: ......
Page 22: ......
Page 32: ......
Page 50: ...Chapter 3 Connecting the Switch to the Network 3 20 ...
Page 51: ...4 Maintenance Powering Down the ARX 500 POST Diagnostics Front Panel LEDs Rear Panel LEDs ...
Page 52: ......
Page 59: ...Index ...
Page 60: ......
Page 62: ...Index Index 4 ...