Environmental operating specifications
This table lists platform environmental operating specifications.
Item
Specification
Operational temperature
32 to 104°F (0 to 40°C)
Operational relative humidity 5% to 85% (40°C) non-condensing
Up to 93% (40°C) non-condensing for a maximum of 96 hours
Non-operational temperature
-40 to 158°F (-40 to 70°C)
Non-operational relative
humidity
5% to 93% (40°C) non-condensing
Power specifications - i2000 (i2600/i2800) Series
This table lists power specifications for i2000 (i2600/i2800) Series platforms.
Item
Single power supply
Dual power supply
Idle power draw (AC power)
110VAC input: 70W
220VAC input: 70W
110VAC input: 80W
220VAC input: 75W
Typical power draw (AC
power; 50% load; temp 25°C)
110VAC input: 95W
220VAC input: 95W
110VAC input: 100W
220VAC input: 100W
Typical power draw (DC
power; 50% load; temp 25°C)
48VDC input: 105W
48VDC input: 115W
Maximum power draw (AC
power)
110VAC input: 120W
220VAC input: 120W
110VAC input: 120W
220VAC input: 120W
Maximum power draw (DC
power)
48VDC input: 125W
48VDC input: 140W
Typical heat generated (AC
power)
110VAC input: 325 BTU/hour
220VAC input: 345 BTU/hour
110VAC input: 325 BTU/hour
220VAC input: 345 BTU/hour
Typical heat generated (DC
power)
48VDC input: 360 BTU/hour
48VDC input: 395W
Maximum heat generated (AC
power)
410 BTU/hour
410 BTU/hour
Maximum heat generated (DC
power)
430 BTU/hour
480 BTU/hour
Important: Specifications are subject to change without notification.
Power specifications - i4000 (i4600/i4800) Series
This table lists power specifications for i4000 (i4600/i4800) Series platforms.
Platform Guide: i2000/i4000 Series
49