AC power supply LEDs
The LEDs located on the AC power supplies indicate the operating state of the power supplies
Input LED
Output LED
Condition
green solid
green solid
Normal operation
off
off
Fault: Input UV, Input OV, VSB SC
off
amber solid
Not valid
green solid
amber solid
Warning: VSB OC
Fault: Fan, OTP, OC, VOUT OV/UV
green solid
amber blinking
Warning: FAN, OTP, OC, VOUT OV/UV
green blinking
amber solid
Fault: Input OV
green blinking
amber blinking
Warning: Input OV, Input UV
green blinking
off
Not valid
green solid
green blinking
PS_ON_L is high
green solid
off
PS_KILL PSU not inserted
OV - Over Voltage; OTP - Over Temperature Protection; UV - Under Voltage; OC - Over Current; VSB -
Standby Voltage
DC power supply LEDs
The LEDs located on the DC power supplies indicate the operating state of the power supplies
Input
LED
Output/Fault
LED
Condition (PWR-0307-01)
Condition (PWR-0307-02 and
later)
green
solid
green solid
Normal operation
Normal operation
off
off
Fault: Input UV
Fault: Input UV, VSB SC
off
amber solid
Fault: Input OV
Not valid
green
solid
amber solid
Warning: VSB OC
Fault: Fan, OTP, OC, VOUT
OV/UV
Warning: VSB OC
Fault: Fan, OTP, OC, VOUT
OV/UV
green
solid
amber blinking
Warning: FAN, OTP, OC, VOUT
OV/UV
Warning: FAN, OTP, OC, VOUT
OV/UV
green
blinking
amber solid
Not valid
Fault: Input OV
green
blinking
amber blinking
Not valid
Warning: Input OV, Input UV
green
blinking
off
Fault/Warning: Input OV
Not valid
green
solid
green blinking
PS_ON_L is high
PS_ON_L is high
Platform Overview
16
Summary of Contents for i5000 Series
Page 1: ...Platform Guide i5000 i7000 i10000 i11000 Series MAN 0633 05...
Page 2: ......
Page 51: ...Figure 17 Airflow in iSeries platforms Platform Guide i5000 i7000 i10000 i11000 Series 51...
Page 52: ...Environmental Guidelines 52...
Page 61: ...Platform Guide i5000 i7000 i10000 i11000 Series 61...
Page 62: ...Platform Specifications 62...
Page 64: ...Repackaging Guidelines 64...