390 / 390 24
ENGLISH
Guide for the installer
Page
Thank you for choosing our product. FAAC is sure that it will give you
all the performances you are looking for. All our products are the
result of a long experience in the field of the automated systems.
In the middle of the handbook you will find a detachable
brochure with the images for the installation.
These instructions apply to the following model:
390
The external automation with articulated arms automates residen-
tial swing-leaf gates with leaves of up to 3m in length, and is ideal
for applications on large pilasters without the need to provide
niches (sometimes required to observe the installation dimensions
of piston driven devices).
It consists of an irreversible electro-mechanical operator with guard
and an articulated-arm activation system to be fitted to the gate
with the appropriate accessories.
The irreversible system ensures the gate is mechanical locked when
the motor is not operating. No lock need be installed for leaves
up to 2m in length.
A manual release makes it possible to move the gate in the event
of a power-cut or fault.
IMPORTANT NOTES FOR INSTALLER
Before starting the installation of the operator read this manual
completely.
Keep this manual for future reference.
Smooth operation and specifications are obtained only declared
following the directions given in this handbook and with acces-
sories and safety devices FAAC.
The lack of a mechanical clutch device requires to ensure an
adequate level of security automation, the use of a central control
device with an electronically controlled clutch.
The automation was designed and built to control vehicular ac-
cess. Avoid any other use.
The operator can not be used to handle emergency exit routes
or gates installed on emergency (escape routes).
If there is built-in anti motorize from a door to the walkway is requi-
red to add a safety switch on the door, connected on the entry of
STOP, to inhibit the operation of automation with door open.
Everything that is not expressly stated in this manual is not al-
lowed.
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
With reference to Figure 1
Pos
Description
a
Guard
b
Operator securing base-plate
c
Release wrench
d
Release
e
Gearmotor
f
Transmission shaft
g
Straight lever of articulated arm
h
Curved lever of articulated arm
i
Front coupling
TAB. 1 TECHNICAL SPECIFICATION OF OPERATOR
MODEL
390
Power supply
230V~ 50Hz
24 Vdc
Power absorption
280 W
40 W
Current absorption
1.2 A
2 A
Max torque
250 Nm
200 Nm
Nominal Torque
170 Nm
140 Nm
Starting capacitor
8 µF
/
Leaf max length
a
3 m
Thermal protection for winding
140 °C
/
Reduction ratio
1:700
Angular velocity
8 °/sec
Ambient temperature
-20 °C +55 °C
Use frequency at 20°C
S3 - 30%
S3 - 100%
Cycles / hour at 20°C
>30
>100
Noise
<70 dB(A)
•
•
•
•
•
•
•
•
MODEL
390
Weight of gearmotor
11.5 Kg
Protection class
IP 44
Gearmotor overall dimension
Vedi Fig. 2
a
An electrolock should be installed in the event of leaves excee-
ding 2 metres, in order to guarantee the leaf blocking.
2. ELECTRICAL EQUIPMENT (standards system)
With reference to Figure 3
Pos.
Description
Cables
230 Vac
24 Vdc
a
Operators
4x1 mm
2
2x1.5mm
2
b
TX photocells
2x0.5 mm
2
c
RX photocells
4x0.5 mm
2
d
Key selector
2x0.5 mm
2
e
Flashing lamp
2x1.5 mm
2
f
Control unit
3x1.5 mm
2
(power supply)
g
Mechanical stops
—
To lay electrical cables, use adequate rigid and/or flexible
tubes.
Always separate low voltage accessories from those ope-
rating at 230 V~. To avoid any interference, always use
separate sheaths.
For the motor cable to use a sheath suitable for outdoor use,
a hand that is piped in special ducts always external use.
3. INSTALLATION OF AUTOMATION
3.1. PRELIMINARY CHECKS
To ensure safety and an efficient automation, make sure the
following requirements are met:
The gate structure must be suitable for automation. In particular,
make sure it is sufficiently sturdy and rigid, and that its dimensions
are in line with those indicated in the technical specifications.
Make sure that the leaves move properly and uniformly, without
any irregular friction during their entire travel.
Check if hinges are in good condition.
Make sure the travel limit mechanical stops are present. We
advise you to carry out any metalwork jobs before installing the
automation.
3.2. INSTALLATION DIMENSIONS
Establish the installation position of the operator by consulting
Fig. 4-5-6.
INWARD OPENING (Fig. 5)
A (mm)
B (mm)
C max. (mm)
a (°)
60 ÷ 110
110 ÷ 130
730
90
110 ÷ 160
720
160 ÷ 210
710
210 ÷ 260
700
260 ÷ 310
690
310 ÷ 360
670
60 ÷ 110
190 ÷ 210
650
120
110 ÷ 160
230 ÷ 250
600
160 ÷ 210
290 ÷ 310
540
210 ÷ 260
310 ÷ 330
510
120
As for 120° openings the curved arm must be fixed to the
hole marked with the letter “
X
”
OUTWARD OPENING (Fig. 6)
A (mm)
B (mm)
C max. (mm)
a (°)
60 ÷ 110
110 ÷ 130
430
90
110 ÷ 160
380
160 ÷ 210
330
210 ÷ 260
280
260 ÷ 310
240
•
•
•
•