background image

390 / 390 24

ENGLISH

Guide for the installer

Page

Thank you for choosing our product. FAAC is sure that it will give you 

all the performances you are looking for. All our products are the 

result of a long experience in the field of the automated systems.

  In the middle of the handbook you will find a detachable 

brochure with the images for the installation.

These instructions apply to the following model:

390

The external automation with articulated arms automates residen-

tial swing-leaf gates with leaves of up to 3m in length, and is ideal 

for  applications  on  large  pilasters  without  the  need  to  provide 

niches (sometimes required to observe the installation dimensions 

of piston driven devices).

It consists of  an irreversible electro-mechanical operator with guard 

and an articulated-arm activation system to be fitted to the gate 

with the appropriate accessories.

The irreversible system ensures the gate is mechanical locked when 

the motor is not operating. No lock need be installed for leaves 

up to 2m in length.

A manual release makes it possible to move the gate in the event 

of a power-cut or fault.

IMPORTANT NOTES FOR INSTALLER

Before starting the installation of the operator read this manual 

completely.

Keep this manual for future reference.

Smooth operation and specifications are obtained only declared 

following the directions given in this handbook and with acces-

sories and safety devices FAAC.

The lack of a mechanical clutch device requires to ensure an 

adequate level of security automation, the use of a central control 

device with an electronically controlled clutch.

The automation was designed and built to control vehicular ac-

cess. Avoid any other use.

The operator can not be used to handle emergency exit routes 

or gates installed on emergency (escape routes).

If there is built-in anti motorize from a door to the walkway is requi-

red to add a safety switch on the door, connected on the entry of 

STOP, to inhibit the operation of automation with door open.

Everything  that  is  not  expressly  stated  in  this  manual  is  not  al-

lowed.

1. DESCRIPTION AND TECHNICAL SPECIFICATIONS

With reference to Figure 1

Pos

Description

a

Guard

b

Operator securing base-plate

c

Release wrench

d

Release

e

Gearmotor

f

Transmission shaft

g

Straight lever of articulated arm

h

Curved lever of articulated arm

i

Front coupling

TAB. 1 TECHNICAL SPECIFICATION OF OPERATOR

MODEL

390

Power supply

230V~ 50Hz

24 Vdc

Power absorption

280 W

40 W

Current absorption

1.2 A

2 A

Max torque

250 Nm

200 Nm

Nominal Torque

170 Nm

140 Nm

Starting capacitor

8 µF

/

Leaf max length 

a

3 m

Thermal protection for winding

140 °C

/

Reduction ratio

1:700

Angular velocity

8 °/sec

Ambient temperature

-20 °C +55 °C

Use frequency at 20°C

S3 - 30%

S3 - 100%

Cycles / hour at 20°C

>30

>100

Noise

<70 dB(A)

MODEL

390

Weight of gearmotor

11.5 Kg

Protection class

IP 44

Gearmotor overall dimension

Vedi Fig. 2

a

 An electrolock should be installed in the event of leaves excee-

ding 2 metres, in order to guarantee the leaf blocking.

2. ELECTRICAL EQUIPMENT (standards system)

With reference to Figure 3

Pos.

Description

Cables

230 Vac

24 Vdc

a

Operators

4x1 mm

2

2x1.5mm

2

b

TX photocells

2x0.5 mm

2

c

RX photocells

4x0.5 mm

2

d

Key selector

2x0.5 mm

2

e

Flashing lamp

2x1.5 mm

2

f

Control unit

3x1.5 mm

(power supply)

g

Mechanical stops

  To lay electrical cables, use adequate rigid and/or flexible 

tubes.

  Always separate low voltage accessories from those ope-

rating  at  230  V~.  To  avoid  any  interference,  always  use 

separate sheaths.

 

For the motor cable to use a sheath suitable for outdoor use, 

a hand that is piped in special ducts always external use.

3. INSTALLATION OF AUTOMATION

3.1. PRELIMINARY CHECKS

  To ensure safety and an efficient automation, make sure the 

following requirements are met:

The gate structure must be suitable for automation. In particular, 

make sure it is sufficiently sturdy and rigid, and that its dimensions 

are in line with those indicated in the technical specifications.

Make sure that the leaves move properly and uniformly, without 

any irregular friction during their entire travel.

Check if hinges are in good condition.

Make  sure  the  travel  limit  mechanical  stops  are  present.  We 

advise you to carry out any metalwork jobs before installing the 

automation.

3.2. INSTALLATION DIMENSIONS

Establish  the  installation  position  of  the  operator    by  consulting 

Fig. 4-5-6.

INWARD OPENING (Fig. 5)

A (mm)

B (mm)

C max. (mm)

a (°)

60 ÷ 110

110 ÷ 130

730

90

110 ÷ 160

720

160 ÷ 210

710

210 ÷ 260

700

260 ÷ 310

690

310 ÷ 360

670

60 ÷ 110

190 ÷ 210

650

120

110 ÷ 160

230 ÷ 250

600

160 ÷ 210

290 ÷ 310

540

210 ÷ 260

310 ÷ 330

510

120

  As for 120° openings the curved arm must be fixed to the 

hole marked with the letter “

X

OUTWARD OPENING (Fig. 6)

A (mm)

B (mm)

C max. (mm)

a (°)

60 ÷ 110

110 ÷ 130

430

90

110 ÷ 160

380

160 ÷ 210

330

210 ÷ 260

280

260 ÷ 310

240

Reviews: