3.3. INSTALLATION STEPS

The operator, base-plate and articulated arm are designed either 

for right-hand or left-hand (Fig. 7) installation.

Secure the base-plate to the pilaster, using Ø10 screws and suita-

ble expansion plugs (Fig. 8), and check it is perfectly horizontal.

Fit the gearmotor unit on the base-plate and secure it with the 

two screws, nuts and flexible washers (Fig.8).

  The transmission shaft must always face downward.

Assemble  the  articulated  arm  and  front  coupling  as  shown  in 

Fig. 9.

Fit the straight lever of the articulated arm on the gearmotor shaft 

and tighten it with the supplied screw and washer (Fig. 10).

Release the operator  (chapter 4.)

Establish the securing position of the front coupling on the leaf, 

observing dimension “

C

” defined previously (chapter 4.2). Check 

that arm and coupling are perfectly horizontal. 

  The coupling may be welded directly onto the leaf (Fig. 11) 

or screwed by using the threaded inserts (Fig. 12).

In both cases, mark the position of the front fitting and provisionally 

remove the coupling from the arm in order to secure it.

After having fastened the front fitting, mount the arm again

Fit the guards on the operator  (Fig. 10).

Re-lock the operator  (chapter 5.)

Make the electrical connections of the selected electronic ap-

pliance, observing the annexed instructions.

3.4. TEST OF THE AUTOMATION

When you have finished installation, carefully check the operating 

efficiency of the automation and of all accessories connected to 

it,  safety devices in particular.

Hand the “User’s Guide” page to the Client, and describe how 

the operator should function  and be used correctly, stressing the 

potentially dangerous areas of the automation.

4. MANUAL OPERATING MODE

If the gate has to be operated manually in the event of a power-cut 

or fault to the automation, use the release device as follows:

  Cut power to the system.

Fit the supplied Allen wrench and turn it by about a half turn until 

it stops, in the direction shown in Fig. 13,  depending on type of 

installation.

Move the gate by hand.

5. RESTORING NORMAL OPERATING MODE

  To avoid an involuntary pulse from activating the gate during 

the manoeuvre, before re-locking the operator , switch off 

power to the system.

Fit the supplied Allen wrench and turn it by about a half turn until 

it stops, in the direction shown in Fig. 13,  depending on type of 

installation.

make sure that the gate cannot be moved manually.

Restore power to the system.

6. MAINTENANCE

To  ensure  correct  long-term  operation  and  a  constant  level  of 

safety,  we  advise  you  to  generally  control  the  system  at  least 

every 6 months. In the “

User’s Guide

” booklet, there is a form for 

recording jobs.

7. REPAIRS

  The User must not in any way attempt to repair or to take direct 

action and must solely contact qualified FAAC personnel or 

FAAC service centres.