Attach the operator to the gate
Re-attach the operator to the mounting brackets. Once the
operator is mounted and level, remove the vent screw from
the bottom of the valve body (Fig. 11). Use a 3mm hex wrench.
WARNING! Failure to remove the vent screw may result in erratic
operation of the operator or blown seals.
Slowly move the gate open and close, the piston should not
bottom out in either direction. Be sure that the gate reaches
the positive stop before the piston bottoms out.
Attach the connector with the cable and secure it with the
supplied screws (Fig 12). Make sure the strain relief is tight on
the connector.
Slip the cover over the operator. The slit in the cover should face
the gate, and the cover should be placed firmly over the rear
of the operator cover (item 1 in Fig 13). Secure the cover to
the operator using the self tapping screw (2).
Fix the end cap (3) to the cover using the black plastic screws
(4).
Fig. 12