background image

6

ENGLISH

ENGLISH

Drawing A

               INSTALLATION DIMENSIONS

b

a

z

d

80

892

Fig. A

Fig. B

Table A: Recommended dimensions

Opening

a

b

c (*)

d (**)

angle "

ααααα

"

(mm)

(mm)

(mm)

(mm)

90°

145

145

290

100

110°

125

125

290

80

(*) working excursion of piston rod

    

(**)maximum dimensions

CALCULATING  INSTALLATION DIMENSIONS:
GENERAL RULES

If modifications to the dimensions specified in Table A
are necessary, proceed as follows:

-

For 

90° leaf opening: a + b = c

-

For 

leaf opening over 90°:

 

a + b < c

-

The lower the dimensions of a and b the higher the gate
speed

. Always respect current standards.

-

Limit the difference between a and b to within 4 cm

: larger

differences alter speed considerably during opening and
closing.

-

For reasons of operator clearance, 

the minimum value for

Z is 45 mm

 (fig. A)

If the dimensions of the gate post or position of the hinge do
not allow for the specified distance of “

a

”, make a recess

in the gate post as shown in fig. B.

300 mm

150 mm

100 mm

412  AUTOMATION SYSTEM

These instructions apply to the following models:

Operators 412 and 412-24V

The FAAC 412 AUTOMATION SYSTEM for swing gates comprises
two electromechanical operators which drive the gate leaves
by means of a worm screw.
The system locks mechanically; therefore no electric lock is
required.

Ü

Ü

Ü

Ü

Ü

To obtain anti-crushing protection, you have to use elec-
tronic control units with a torque control electronic device.

The 412 automation was designed and manufactured to con-
trol access of vehicles.
Avoid any other use whatever.

1. DESCRIPTION AND TECHNICAL SPECIFICATIONS

Table 1: 412 operator  technical specifications

412

412-24V

Power supply

230 V~ 50 Hz

24Vdc

Absorbed power (W)

280

70

Current drawn (A)

1,5

3

Electric motor

1400  rpm

Motor winding thermal cutout

140 °C

/

Capacitor

8 µF/400V

/

Max. thrust/traction force (daN)

350

250

Rod stroke (mm)

290

Rod speed (cm/s)

1,6

Temperature range (°C)

-20 

v

 +55 °C

Operator weight (Kg)

6,5

Housing protection

IP 44

Duty cycle (cycles/hour )

18

50

Maximum leaf length (m)

1,80

Fig. 1

1

6

2

5

7

3

4

a

Motor Unit

b

Power cable

c

Worm screw

d

Front bracket

e

Rear bracket

f

Cable cover

g

Cover

Reviews: