8
ENGLISH
ENGLISH
N.B
.: 1) Grease all pivots on brackets
2) If welding is not possible, the front and rear
bracket plates are also designed for fixing by
screws and screw anchors.
12) Fit the cover (fig. 7) on the operator as shown in fig. 8.
N.B.:
Fix the guide support of the cover on the hole furthest
from the cap (fig.7).
13) Repeat the above operations to install the second operator.
14) Make the control unit connections.
15) Programme the control unit to set the specific installation
requirements.
Fig. 9
Fig. 10
SBLOCCA
DESBLOQUEAR
DEBLOQUE
UNLOCK
ENTRIEGELT
BLOCCA
BLOQUEAR
BLOQUE
LOCK
VERRIEGELT
SBLOCCA
DESBLOQUEAR
DEBLOQUE
UNLOCK
ENTRIEGELT
BLOCCA
BLOQUEAR
BLOQUE
LOCK
VERRIEGELT
4. TESTING THE AUTOMATED UNIT
On completing installation, affix a danger warning adhesive
label in a clearly visible position on the side of the operator (fig.
9).
Careful check operation of the operator and all accessories
connected to it.
Give the customer the “User guide” and demonstrate how to
use the operator correctly. Point out the potential danger
zones of the automated unit.
5. MANUAL OPERATION
In the event of a power failure or malfunction, the gate can be
operated manually by removing the plug and inserting the
special release key as shown in fig. 10.
To release the operator, turn the key in the direction of leaf
closing (fig. 10).
Open or close the leaves manually.
6. RETURNING TO NORMAL OPERATION
Turn off the electricity supply to the system before re-locking
the operators to avoid all risk of starting them accidentally.
To re-lock the operator, turn the key in the leaf opening
direction (fig. 10).
Fig. 7
Fig. 8
7. SPECIAL APPLICATIONS
There are no special applications.
8. MAINTENANCE
Carry out periodic checks of the gate structure and ensure in
particular that the hinges are in perfect working condition.
Check periodically that the electronic anti-crushing system is
adjusted correctly and that the release mechanism for manual
movement is fully operative (see relative paragraph).
Safety devices installed on the plant must be checked every
six months.
9. REPAIRS
For repairs, refer to authorised FAAC service centres.