1) IMPORTANT! FAAC strongly recommends to follow these instructions

carefully for the safety of persons. Improper installation or misuse of
the product will cause very serious damages to persons.

2) Read the instructions carefully  before installing the product.

3) Packaging materials (plastic, polystyrene etc.) are a potential hazard

and must be kept out of reach of children.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use

stated in this manual. Any other use not expressly set forth will affect the
reliability of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by

improper use or different from the use for which the automation system is
destined to.

7) Do not use this device in areas subject to explosion: the presence of

flammable gas or fumes is a serious hazard.

8) Mechanical constructive elements must comply with UNI 8612, CEN prEN

12604 and CEN prEN 12605 standards.

Countries outside the EC shall follow the regulations above besides their
national normative references in order to offer the utmost safety.

9) Faac cannot be held responsible for failure to observe technical stan-

dards in the construction of gates and doors, or for any deformation of
the gates which may occur during use.

10) Installation must comply with UNI8612, CEN pr EN 12453 and CEN pr EN

12635.
The degree of safety of the automation must be C+D.

10A) IEC 335-2-95

11) Before attempting any job on the system or operator, cut out electric

power and disconnect the batteries, if installed.

12) An omnipower switch shall be provided for the installation with an open-

ing distance of the contacts of 3 mm of more. Alternatively, use a 6A

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

(DIRECTIVE 89/392 EEC, APPENDIX II, PART B)

Manufacturer:

       FAAC S.p.A.

Address:

       Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Hereby declares that: 

the 525/530 automation system

• is intended to be incorporated into machinery, or to be assembled with other machinery to constitute

machinery in compliance with the requirements of Directive 89/392 EEC, and subsequent amendments 91/
368 EEC, 93/44 EEC and 93/68 EEC;

• complies with the essential safety requirements in the following EEC Directives:

73/23 EEC and subsequent amendment 93/68 EEC.
89/336 EEC and subsequent amendments 92/31 EEC and 93/68 EEC.

and furthermore declares that unit must not be put into service until the machinery into which it is incorporated
or of which it is a component has been identified and declared to be in conformity with the provisions of
Directive 89/392 EEC and subsequent amendments enacted by the national implementing legislation.

Bologna, 1 January 1999

Managing Director

A.Bassi

thermomagnetic breaker with multi-pole switching.

13) Ensure that there is a differential switch up-line of the electrical system,

with a trip threshold of 0.03 A.

14) Check that the earthing plant is in perfect condition and connect it to

the metallic parts. Also earth the yellow/green wire of the operator.

15) The automation is fitted with an anti-crush safety system that is a torque

control device. In any case, further safety devices shall be installed.

16) The safety devices (e.g.photocells, safety edges, etc.) protect areas

where there is a  

mechanical movement hazard,

 e.g. crushing, entrap-

ment and cutting.

17) Each installation must be fitted with at least one flashing light (e.g. FAAC

LAMP, MINILAMP, etc.) as well as a warning plate suitably fixed to the
gate, besides the safety devices as per point 16 above.

18) Faac cannot be held responsible regarding safety and correct function-

ing of the automation in the event that parts other than Faac original
parts are used.

19) Use only Faac original spare parts for maintenance operations.

20) Do not carry out any modifications to automation components.

21) The installer must supply all information regarding manual operation of

the system in the event of an emergency and provide the end-user with
the ”End-user Guide” attached to the product.

22) Do not allow children or adults to stand near the product during opera-

tion.

23) Keep out of reach of children the remote radio controls and any control

devices. The automation could be operated unintentionally.

24) The end-user must avoid any attempt to repair or adjust the automation

personally. These operations must be carried out exclusively by qualified
personnel.

25) What is not explicitly stated in these instructions is not permitted.

IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

Summary of Contents for 525

Page 1: ...nt amendments 91 368 EEC 93 44 EEC and 93 68 EEC complies with the essential safety requirements in the following EEC Directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent...

Page 2: ...temsweredesignedandbuilt for indoor use and for controlling vehicle access Avoid any other use 2 DIMENSIONS Fig 1 Fig 2 Power pipe 230V Cable 4 x 0 5 RX photocell Cable 3x0 5 Radio receiver Cable 2 x...

Page 3: ...by the automatic system Check if an efficient earth plate is available for electrical connection to the operator Make sure there is a clearance of at least 35 mm between the ceiling and the highest sl...

Page 4: ...e advise you to use the optional guide fig 8 ref B fitting it on the central slide fig 8 ref C 5 3 Insert the longitudinal member with chain in the central slide fig 9 until it meets the metal project...

Page 5: ...N B To apply tension to the chain turn the nut clock wise To slacken the chain turn the nut anti clock wise Warning too much chain tension could damage the motor unit 5 6 Offer the assembled guide to...

Page 6: ...spect to the door use a spirit level 6 8 When you have reached the correct position measure the distance between ceiling and operator so that you can shape the securing brackets in advance 6 9 Fit the...

Page 7: ...distance between drive bracket and sliding rail bracket must not exceed 20cm max 30 fig 24 6 22 Check the position drill and secure with suitable screws fig 24 Fig 25 LOCK Fig 26 6 23 Re lock the aut...

Page 8: ...Open push button P2 Set up push button LK1 Enable disable fail safe LK2 Varies sensitivity of reversing device Fig 27 fail safe enabled fail safe disabled LK1 reversing sensitivity 150N 15Kg LK2 rever...

Page 9: ...es to vary the sensitivity of the reversing device fig 27 Fig 28 OTHERSAFETYDEVICES STOP OPEN 8 ANTENNAINSTALLATION OPTIONAL 8 1 If you are using an RP receiver and wish to increase its range you can...

Page 10: ...ing push button dismantle the cour tesy light ceiling fixture unscrewing the appropriate screw Slidetheceilingfixtureinthedirectionshownbythearrow fig 34 INITIAL SET UP The obstacle detector does NOT...

Page 11: ...tronic appliance establishes the deceleration points and pause time is fixed at 3 minutes If the SETUP procedure was successful the courtesy lamp stays lightedfor5seconds Duringthistime inordertoreduc...

Page 12: ...tomated system and safety devices and then apply the danger warning sticker fig 35 on the panel of the up and over door to make it easy to see Apply the sticker which indicates the release device of t...

Page 13: ...n electronic device ensures that any obstacles are detected The door is normally closed when the electronic control unit receives an opening commandfromtheremotecontrol orfromanyothertypeofpulsegenera...

Reviews: