background image

14

ENGLISH

ENGLISH

AUTOMATIC SYSTEM 565/570/575

These instructions apply to the following models:

565 - 570 - 575

Automatic systems 565-570-575 are designed to automate over-
head spring-balanced, sectional, and counterbalanced (with
special GDA 3000 accessory)  doors for residential garages.
They consist of an electro-mechanical operator, electronic con-
trol appliance and courtesy lamp built into a single unit.  The unit
is fitted to the ceiling and opens the door  by means of a
transmission chain.
The system is non-reversing and, therefore, the door locks me-
chanically when the motor is not operating and, consequently,
no other lock is necessary; two manual releases on the inside and
outside (optional) make it possible to move the door manually in
case of a power cut or fault.
Any obstacles are certain to be detected by a controlling
electronic device which comes into action while the automatic
system is in operation.

The 565-570 and 575 automated systems were designed and built
for indoor use and for controlling vehicle access.Avoid any other
use.

2. DIMENSIONS

Fig.1

Fig.2


‚

ƒ

„

…

Power pipe (230V)

Cable 4 x 0,5 (RX photocell)

Cable 3x0.5 (Radio receiver)

Cable 2 x 0,5 (TX photocell)

Low voltage pipe

†

Cable 2 x 1.5 + earth (power supply)

3. ANCILLARY ELECTRICAL EQUIPMENT

1. DESCRIPTION AND TECHNICAL SPECIFICATIONS

328

157

415

2738 (565)/ 3338 (570)/3938(575)

Dimensions in mm

MODEL

                   565

         570                   575

Power  supply

    

            230V ac  50Hz

Electric motor

      24V dc

Maximum absorbed power

   

                     220W

Maximum  cycles  per  hour

     

           20 (with load of  56Kg at 20°C)

Maximum  consecutive  cycles

                    

6 (at 20°C)

Minimum  distance  from  ceiling

     

                           35mm (Fig.4 and 5 )

Maximum  available  travel

           

   1900mm      2500mm        3100mm

Pulling/thrust  power

             

   1200N (~120Kg)

Courtesy  light

    

                           230V ac 40W max

Courtesy light timer

  

                                       2 minutes

Carriage speed (load free)

                    12 cm/sec.

Deceleration  speed

        

                                6 cm/sec.

Deceleration travel                                

                 Varies according to setup

Internal safety device

                       

                 

Type 2

Response time of built-in safety

     

               150msec

device
Door  max  width

         

                          3000 mm (5000mm sectional)

Door max height

                        See max available travel

Protection  class

                           

IP20

Ambient  temperature

               

                                       -20 / +55°C

1

2

3

4

5

6

Summary of Contents for 565

Page 1: ...apier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001...

Page 2: ...uent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complies with the essential safety requirements in the following EEC Directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequen...

Page 3: ...systemsweredesignedandbuilt forindooruseandforcontrollingvehicleaccess Avoidanyother use 2 DIMENSIONS Fig 1 Fig 2 Power pipe 230V Cable 4 x 0 5 RX photocell Cable 3x0 5 Radio receiver Cable 2 x 0 5 TX...

Page 4: ...by the automatic system Check if an efficient earth plate is available for electrical connection to the operator Make sure there is a clearance of at least 35 mm between the ceiling and the highest sl...

Page 5: ...8 ref C centrally with respect to the slide Pre form the brackets and secure them to the guide with the nut Fig 8 5 3 Insert the longitudinal member with chain in the central slide fig 9 until it mee...

Page 6: ...cated in fig 15 ref C N B To apply tension to the chain turn the nut clock wise To slacken the chain turn the nut anti clock wise Warning too much chain tension could damage the motor unit 5 6 Offer t...

Page 7: ...spect to the door use a spirit level 6 8 When you have reached the correct position measure the distance between ceiling and operator so that you can shape the securing brackets in advance 6 9 Fit the...

Page 8: ...distance between drive bracket and sliding rail bracket must not exceed 20cm max 30 fig 24 6 22 Check the position drill and secure with suitable screws fig 24 Fig 25 Fig 26 6 23 Re lock the automati...

Page 9: ...ontact supplies an opening or closing pulse to the door To install several Open devices connect N O contacts in parallel STOP Stopcommand N C Any device e g a push button which by opening a contact st...

Page 10: ...es to vary the sensitivity of the reversing device fig 27 Fig 28 8 ANTENNAINSTALLATION OPTIONAL 8 1 If you are using an RP receiver and wish to increase its range you can use an external 433 MHZ anten...

Page 11: ...propriate screw Slidetheceilingfixtureinthedirectionshownbythearrow fig 34 SET UP CYCLE During this procedure the obstacle detection and Fail safe device are NOT operating The set up cycle defines ant...

Page 12: ...sy lamp stays lightedfor5seconds Duringthistime inordertoreducetheload onthereleasesystem openpulsescanbesentwithin2seconds of each other to reverse the release carriage A pulse equals travelof5millim...

Page 13: ...ted system and safety devices and then apply the danger warning sticker fig 35 on the panel of the up and over door to make it easy to see Apply the sticker which indicates the release device of the a...

Page 14: ...or fault An electronic device ensures that any obstacles are detected The door is normally closed when the electronic control unit receives an opening commandfromtheremotecontrol orfromanyothertypeof...

Page 15: ......

Page 16: ...e a poner al d a la presente publicaci n todas las modificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial...