18
ENGLISH
ON
OFF
SW2
ON
OFF
FSW
opens on disengagement
opens immediately
SW5
ON
OFF
PAUSE TIME
60"
30"
SW3
ON
OFF
ON
OFF
SW4
ON
ON
OFF
OFF
OPEN/CLOSE TIMES
25"
30"
35"
40"
Table 4
SW1
ON
OFF
FAIL SAFE
YES
NO
SW6
ON
OFF
1 2 3 4 5 6
LOGIC
A
E
LOGICS "A"
DOOR STATE
OPEN
STOP
Table 5/a
CLOSED
No effect
No effect (OPEN inhibited)
STOPPED
No effect (OPEN inhibited)
Closes the door
Stops
Opens the door and recloses after pause time
Recloses the door immediately
Reopens the door immediately
PULSES
SAFETIES
No effect
Freezes pause until disengagement (OPEN inhibited)
See paragraph 5.2.2
No effect
No effect (OPEN inhibited)
LOGICS "E"
DOOR STATE
OPEN
STOP
Table 5/b
CLOSED
No effect (OPEN inhibited)
STOPPED
No effect (OPEN inhibited)
Closes the door
Stops
Opens the door and recloses after pause time
Recloses the door immediately
Reopens the door immediately
PULSES
SAFETIES
No effect
Freezes pause until disengagement (OPEN inhibited)
See paragraph 5.2.2
No effect
No effect (OPEN inhibited)
Recloses the door immediately
CLOSING
OPEN on PAUSE
OPENING
OPEN on PAUSE
CLOSING
OPENING
6. START-UP
Program electronic control unit 596 MPS according to your
requirements as shown in table 4.
6.1.
DIRECTION OF ROTATION
1)
Switch off the power.
2)
Move the door manually to the halfway position.
3)
Lock the operator.
4)
Switch on the power.
5)
Send an OPEN pulse to the input (fig. 20) and check
that this makes the door open.
If the gate closes, invert the motor wires on the control unit
(brown and black wires).
6.2.
OPERATING TIME SELECTION
Select an operating time a few seconds longer than the
one previously timed on the electronic control unit 596 MPS
in order to obtain maximum efficiency of the hydraulic
lock.
6.3.
SELECTING PAUSE TIME
By selecting logic A it is possible to regulate the garage
door pause time by way of the relevant dip-switch.
6.4.
SELECTING FAIL-SAFE
The 596 MPS card also has a FAIL-SAFE safety device which
serves to verify that the N.C. contact on the photocell
receiver is working correctly before each operation; this
device can be disabled.