4.4. ADJUSTING THE BALANCE SPRING

IMPORTANT!: The barrier is supplied already balanced for
the exact beam length specified in the order.  See "ORDER
CODE TABLE" on price list.

Should a fine adjustment of the beam balance be needed,
proceed as follows:

1)

Unlock the operator as described in paragraph 6.

2)

Adjust the pre-loading ring nut (3, Fig. 14) .
The beam is correctly balanced when it remains steady
in the 0° and 90° positions.
If the beam tends to close, turn the ring nut clockwise.
If it tends to open, turn the ring nut counterclockwise.

5. START-UP

5.1. CONNECTING THE ELECTRONIC UNIT

Important!  Disconnect the power supply before you perform
any type of operation (connections, programming or
maintenance) on the electronic unit.
Warning: When terminal strip J2 is disconnected, the power
supply outputs of the motor, fan and flashing lamp are still
connected to the electric power supply.

Follow points 10, 11, 12, 13 and 14 of the GENERAL SAFETY
REGULATIONS.
Position the pipes as shown in Figure 3.
Keep the power supply cables separate from the control
and safety signal cables (photocells, receiver, pushbutton,
etc.). Use separate sheaths to avoid any interference.
Make the electrical connections between the 625 MPS
control unit and the chosen accessories, referring to fig. 16
for automatic logic A or semiautomatic logic E, and fig. 17
for parking logic P.

Table 3

Technical characteristics of 625MPS

Fig. 14

(*) P logic operation
(**) A / E logic operation

Table 4

Operation of Status LEDS

1

2

 3

5.2. CONNECTING RADIO RECEIVERS

Use quick connector J4 to insert
one of the decoder or receiver
cards RP shown in boxes A - B - C.
Fit it with the components
oriented towards the centre of
the 625 MPS card.

Table 2

625 MPS CONTROL UNIT

Fig. 15

TF1

TRANSFORMER

J1

REMOVABLE LOW-VOLTAGE TERMINAL
STRIP

J2

REMOVABLE POWER TERMINAL STRIP

J3

LIMIT SWITCH CONNECTOR

J4

DECODER CONNECTOR

J5

CONNECTOR FOR FSW, SLAVE, RELAY
BOARDS

J6

CONNECTOR FOR NTC PROBE

J9

REMOVABLE MAINS POWER TERMINAL
STRIP

P1

RESET PUSHBUTTON

F1

F5A FUSE (MOTOR)

F2

T1.6A FUSE (ACCESSORIES)

DS1

PROGRAMMING MICROSWITCHES

DL1

OPEN IMPULSE LED  (A/E/P LOG.)

DL2

CLOSE IMPULSE LED (P LOG.)
SAFETY CONTACT (A LOG.)

DL3

STOP IMPULSE LED

DL4

ALARM LED (PANIC)

DL5

OPENING LIMIT SWITCH LED

DL6

CLOSING LIMIT SWITCH LED

R

625 MPS

DL1

DL5

DL2 DL3 DL4

DL6

DECODER

RESET

F2

J2

J9

F1

TF1

J3

J5

DS1

J6

P1

J4

J1

DL1

DL5

DL2 DL3 DL4

DL6

625 MPS

DECODER
SL - SLP DS

625 MPS

MINIDEC
SL/DS

PLUS

625 MPS

A

B

C

POWER SUPPLY

230 V (+6 -10 %) 50 Hz

MAX. MOTOR LOAD

300 W

MAX. ACCESSORY LOAD

500 mA

MAX. WARNING LIGHT POWER

5 W (24 Vac)

TEMPERATURE RANGE

- 20°C to 55°C

LED

ON (contact closed)

OFF (contact open)

FCC

closing limit switch not engaged

closing limit switch engaged

FCA

opening limit switch not engaged

opening limit switch engaged

OPEN

activated

deactivated

CLOSED/FSW

activated (*)/saf. disengaged (**)

deactivated (*)/saf. engaged (**)

STOP

deactivated

activated

ALARM

panic contact deactivated

panic contact activated

BEAM

LENGTH

(m)

2.25 - 2.50

2.50 - 3.00

2.50 - 3.00

2.25 - 2.50

2.50 - 3.00

SPRING

LENGTH

(mm)

300

300

300

300

300

SPRING

CODE

721099

721098

721099

721099

721098

DIAMETER OF

SPRING WIRE

(mm)

4,5

5

4,5

4,5

5

BALANCE SPRING FOR RIGID BEAMS

BEAM

PROFILE

620 SR

RECTANGULAR

620 SR ROUND

620 SR ROUND

PIVOTING

Reviews: