IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

1) WARNING!

 

FAAC strongly recommends to follow these instructions literally for the safety of persons. Improper

installation or misuse of the product will cause very serious damages to persons.

2) Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children.

3) Read the instructions carefully before installing the product.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly

set forth will affect the reliability of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by improper use or different from the use for which

the automation system is destined to.

7) Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.

8) Mechanical constructive elements must comply with UNI8612, CEN pr EN 12604 and CEN pr EN 12605 standards.

Countries outside the EC shall follow the regulations above besides their national normative references in order to
offer the utmost safety.

9) FAAC cannot be held responsible for failure to observe technical standards in the construction of gates and doors,

or for any deformation of the gates which may occur during use.

10) Installation must comply with UNI8612, CEN pr 12453 and CEN pr EN 12635.

The degree of safety of the automation must be C + E.

11) Before carrying out any operations, turn off the system’s main switch.

12) An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.

Alternatively, use a 6A thermomagnetic breaker with multi-pole switching.

13) Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.

14) Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the yellow/green

wire of the operator.

15) The automation is fitted with an anti-crush safety system that is a torque control device. In any case, further safety

devices shall be installed.

16) The safety devices (e.g. photocells, safety edges, etc.) protect areas wherethere is a mechanical movement

hazard, e.g. crushing, entrapment and cutting.

17) Each installation must be fitted with at least one fashing light (e.g. FAAC LAMP, MINILAMP etc) as well as a warning

plate suitably fixed to the gate, besides the safety devices as per point 16. above.

18) FAAC cannot be held responsible regarding safety and correct functioning of the automation in the event that parts

other than FAAC original parts are used.

19) Use only FAAC original spare parts for maintenance operations.

20) Do not carry out any modifications to automation components.

21) The installer must supply all information regarding manual operation of the system in the event of an emergency

and provide the end-user with the leaflet attached to the product.

22) Keep out of persons when the product is in operation.

23) Keep out of reach of children the remote radio controls and any control devices. The automation could be

operated unintentionally.

24) The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be

carried out exclusively by qualified personnel.

25) What is not explicitly stated in these instructions is not permitted.

Summary of Contents for 620 STANDARD

Page 1: ...lich 100 Altpapier pour la nature papier recyclé 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado 620 640 642 624 MPS C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 ...

Page 2: ...p A Bologna 20 de diciembre de 1995 Presidente Administrador Delegado KONFORMITÄTSERKLÄRUNG NACH ISO IEC NORM RICHTLINIE 22 EN 45014 HERSTELLERNAME FAAC S p A HERSTELLERANSCHRIFT FAAC S p A Via Benini 1 40069 Zola Predosa BOLOGNA ITALY Hiermit erklären wir eigenverantwortlich daß die Produkte Modelle Serie 402 422 400 750 760 746 844 820 860 590 1 593 580 595 550 500 RC 503 RC 560 630 620 640 642 ...

Page 3: ... subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendments 92 31 EEC and 93 68 EEC and furthermore declares that unit must not be put into service until the machinery into which it is incorporated or of which it is a component has been identified an...

Page 4: ... shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up line of the electrical system with a trip threshold of 0 03A 14 Check that the earthing plant is in perfect condition and connect it to the metallic parts Also earth the yellow green...

Page 5: ...ndcablepassagehole 19 Anchor bolt 20 Baseplate 21 Right handcablepassagehole 22 Earth connector fixing screw 23 Cablepipe 24 624 MPS electronic control unit 25 Right handconnectingpipe 26 Unlocking lever 27 Support position for 460 mm spring 28 Air intake grille 29 Right handpiston 30 Support position for400 mm spring 31 Balancespringsupport 32 Balancespring 33 Right handpistonbleedscrew 34 Therma...

Page 6: ... automation system make sure that the following requirements are met During its movement the beam does not strike against obstacles or overhead power cables The characteristics of the ground must ensure sufficient support for the foundation plinth There must be no pipes or electrical cables in the area to be dug for installing the foundation plinth If the housing is located in a vehicle transit ar...

Page 7: ...alled with the door on the premises side 2 Set up the operator for manual operation as described in section 6 Fig 8 3 Remove the two breather screws as shown in Figure 9 and keep them in a safe place 4 Assemble the beam using the screws supplied as shown in Figures 10 and 10 b Apply the cap to the hole 620 only The rubber edged side of the beam must be in the closing direction 5 Adjust the mechani...

Page 8: ...SORIES LED ON contact closed OFF contact open FCC closing limit switchnot engaged closing limit switch engaged FCA opening limit switchnot engaged opening limit switch engaged OPEN activated deactivated CLOSED FSW activated saf disengaged deactivated saf engaged STOP deactivated activated ALARM beammoving beamstationary WARN LIGHT see warn light operation see warn lightoperation POWER motor power ...

Page 9: ...ec the closing movement is reversed at once ALARM CONDITION It arises in the following cases 1 Enabling of anti panic input 2 Activation of safety TIME OUT device which interrupts the operation of the system when operating time exceeds 30 sec 3 Simultaneous triggering of the two limit switches 4 Microprocessor reading anomaly syncro The alarm condition is indicated by the quick flashing 0 25 sec o...

Page 10: ...m away from the limit switch 3 Re lock the system see paragraph 6 and carry out a few test cycles in order to check whether the positioning of the limit switches the balancing of the spring and the transmitted torque are correct 5 4 TESTING THE AUTOMATION SYSTEM Once installation is complete affix the danger warning adhesive on the top of the housing Fig 18 Carry out a thorough functional check of...

Page 11: ...EGELT BLOQUEAR SBLOCCA UNLOCK DEBLOQUE ENTRIEGELT DESBLOQUEAR BLOCCA LOCK BLOQUE VERRIEGELT BLOQUEAR SBLOCCA UNLOCK DEBLOQUE ENTRIEGELT DESBLOQUEAR Fig 19 b Fig 20 8 2 BLEEDING AIR FROM THE HYDRAULIC CIRCUIT If the beam moves in an irregular manner this may be due to the presence of air in the hydraulic circuit 1 Remove the breather screw Fig 9 2 Actuate the beam electrically while the beam is ope...

Page 12: ...e skirt kit is fitted the balance spring must be adjusted ARTICULATION KIT Fig 25 mod 620 only The articulation kit makes it possible to articulate the rigid beam to a maximum ceiling height of 3 m IMPORTANT If the articulation kit is fitted the balance spring must be adjusted END FOOT Fig 26 The end foot supports the beam in closed position and prevents it from bending downwards IMPORTANT If the ...

Page 13: ...mounted in an enclosure which assures adequate protection against atmospheric agents and can be fitted inside the housing The normal position of the beam is closed in a horizontal position When the electronic control unit receives an opening command from the remote radio control or any other control device it activates the hydraulic system and causes the beam to rotate upwards by 90 to the vertica...

Reviews: