background image

13

ENGLISH

AUTOMATION SYSTEMS 620 - 640 - 642 & 624 MPS

The automation system consists of a white aluminium
beam with red reflectors and of a cataphoresis treated
steel housing with polyester finish.
The housing contains the operator, which consists of a
hydraulic power unit and two pistons. The latter actuate
the rotation of the beam by means of a rocker arm.
A spring mounted on one of the pistons balances the
beam. The housing also contains the electronic control
unit, which is fitted in a watertight container.
The system has an adjustable anti-crushing safety system,
a device that stops and locks the beam in any position,
and a convenient manual release device to be used in
the event of a power failure or malfunction.

Automation systems 620, 640 and  642 & 624 MPS have
been designed and manufactured to control the access of
vehicles. No other use is allowed.

10

 1

 2

 3

 4

 5
 6

 7
 8
 9

11

12
13

14

15

16

17

18

19

20

21

22

23

24

26

25

27

28

29

30

31

32

33

34

35

36

37

Fig. 1

1

Beam

2

Left-hand stroke mechanical stop

3

Drive transmission group

4

Right-hand stroke limit adjustable cam

5

Left-hand stroke limit adjustable cam

6

Rocker arm

7

Left-hand limit switch

8

Oil filler cap

9

Breather screw

10

Cooling fins

11

Left-hand piston bleeder screw

12

Left-hand piston

13

Hydraulic power unit

14

Left-hand connecting pipe

15

Red bypass screw

16

Green bypass screw

17

Housing

18

Left-hand cable passage hole

19

Anchor bolt

20

Base plate

21

Right-hand cable passage hole

22

Earth connector fixing screw

23

Cable pipe

24

624 MPS electronic control unit

25

Right-hand connecting pipe

26

Unlocking lever

27

Support position for 460 mm spring

28

Air intake grille

29

Right-hand piston

30

Support position for400 mm spring

31

Balance spring support

32

Balance spring

33

Right-hand piston bleed screw

34

Thermal probe
(620 rapid and 640 only)

35

Right-hand limit switch

36

Balance adjuster nut

37

Right-hand stroke mechanical stop

38

39

40

41

38

Lock

39

Door

40

Air intake grilles

41

Cooling fan
(620 Rapid and 640 only)

Fig. 2

BARRIER MODEL

620/642

620/642

640/642

RAPID

STANDARD

STANDARD

2

2

Max. beam length (m)

2.5

4

2.5

4

4

6

7

3

3

5

Max. opening time (s)

<2

<3

3,5

4,5

4

5,5

8

(braking excluded)
Angular velocity (r.p.m.)

7.5

5

4.2

3.3

3.7

2.7

1.8

Pump flow rate (l/min)

2

1.5

1

0.75

2

1.5

1

Max. torque (Nm)

90

110

150

200

210

340-370

250

Types of beams

Rigid/Skirt/Articulated

Duty cycle

100%

70%

100%

Power supply

230 V~ (+6 -10 %) 50 Hz

Absorbed  power  (W)

220

Oil type

FAAC XD 220

Oil quantity (l)

2

Motor winding thermal cutout

120° C

Anti-crushing system

bypass valves fitted as standard

Temperature range

-20 to +55 °C

Casing protective treatment

cataphoresis

Casing finish

RAL 2004 polyester

Housing protection

IP 54

Weight (kg)

73

84

Housing dimension WxHxD (mm)

see Figures 4 and 5

Technical characteristic of electric motor

Speed (Rpm)

2,800

1,400

Power (W)

200

200

Current drawn (A)

1

1.2

Power supply

230V~  (+6 -10 %) 50 Hz

1. DESCRIPTION AND TECHNICAL CHARACTERISTICS

Tab. 1 Technical characteristics of barriers

Summary of Contents for 620 STANDARD

Page 1: ...lich 100 Altpapier pour la nature papier recyclé 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado 620 640 642 624 MPS C ERME T A Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 ...

Page 2: ...p A Bologna 20 de diciembre de 1995 Presidente Administrador Delegado KONFORMITÄTSERKLÄRUNG NACH ISO IEC NORM RICHTLINIE 22 EN 45014 HERSTELLERNAME FAAC S p A HERSTELLERANSCHRIFT FAAC S p A Via Benini 1 40069 Zola Predosa BOLOGNA ITALY Hiermit erklären wir eigenverantwortlich daß die Produkte Modelle Serie 402 422 400 750 760 746 844 820 860 590 1 593 580 595 550 500 RC 503 RC 560 630 620 640 642 ...

Page 3: ... subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendments 92 31 EEC and 93 68 EEC and furthermore declares that unit must not be put into service until the machinery into which it is incorporated or of which it is a component has been identified an...

Page 4: ... shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up line of the electrical system with a trip threshold of 0 03A 14 Check that the earthing plant is in perfect condition and connect it to the metallic parts Also earth the yellow green...

Page 5: ...ndcablepassagehole 19 Anchor bolt 20 Baseplate 21 Right handcablepassagehole 22 Earth connector fixing screw 23 Cablepipe 24 624 MPS electronic control unit 25 Right handconnectingpipe 26 Unlocking lever 27 Support position for 460 mm spring 28 Air intake grille 29 Right handpiston 30 Support position for400 mm spring 31 Balancespringsupport 32 Balancespring 33 Right handpistonbleedscrew 34 Therma...

Page 6: ... automation system make sure that the following requirements are met During its movement the beam does not strike against obstacles or overhead power cables The characteristics of the ground must ensure sufficient support for the foundation plinth There must be no pipes or electrical cables in the area to be dug for installing the foundation plinth If the housing is located in a vehicle transit ar...

Page 7: ...alled with the door on the premises side 2 Set up the operator for manual operation as described in section 6 Fig 8 3 Remove the two breather screws as shown in Figure 9 and keep them in a safe place 4 Assemble the beam using the screws supplied as shown in Figures 10 and 10 b Apply the cap to the hole 620 only The rubber edged side of the beam must be in the closing direction 5 Adjust the mechani...

Page 8: ...SORIES LED ON contact closed OFF contact open FCC closing limit switchnot engaged closing limit switch engaged FCA opening limit switchnot engaged opening limit switch engaged OPEN activated deactivated CLOSED FSW activated saf disengaged deactivated saf engaged STOP deactivated activated ALARM beammoving beamstationary WARN LIGHT see warn light operation see warn lightoperation POWER motor power ...

Page 9: ...ec the closing movement is reversed at once ALARM CONDITION It arises in the following cases 1 Enabling of anti panic input 2 Activation of safety TIME OUT device which interrupts the operation of the system when operating time exceeds 30 sec 3 Simultaneous triggering of the two limit switches 4 Microprocessor reading anomaly syncro The alarm condition is indicated by the quick flashing 0 25 sec o...

Page 10: ...m away from the limit switch 3 Re lock the system see paragraph 6 and carry out a few test cycles in order to check whether the positioning of the limit switches the balancing of the spring and the transmitted torque are correct 5 4 TESTING THE AUTOMATION SYSTEM Once installation is complete affix the danger warning adhesive on the top of the housing Fig 18 Carry out a thorough functional check of...

Page 11: ...EGELT BLOQUEAR SBLOCCA UNLOCK DEBLOQUE ENTRIEGELT DESBLOQUEAR BLOCCA LOCK BLOQUE VERRIEGELT BLOQUEAR SBLOCCA UNLOCK DEBLOQUE ENTRIEGELT DESBLOQUEAR Fig 19 b Fig 20 8 2 BLEEDING AIR FROM THE HYDRAULIC CIRCUIT If the beam moves in an irregular manner this may be due to the presence of air in the hydraulic circuit 1 Remove the breather screw Fig 9 2 Actuate the beam electrically while the beam is ope...

Page 12: ...e skirt kit is fitted the balance spring must be adjusted ARTICULATION KIT Fig 25 mod 620 only The articulation kit makes it possible to articulate the rigid beam to a maximum ceiling height of 3 m IMPORTANT If the articulation kit is fitted the balance spring must be adjusted END FOOT Fig 26 The end foot supports the beam in closed position and prevents it from bending downwards IMPORTANT If the ...

Page 13: ...mounted in an enclosure which assures adequate protection against atmospheric agents and can be fitted inside the housing The normal position of the beam is closed in a horizontal position When the electronic control unit receives an opening command from the remote radio control or any other control device it activates the hydraulic system and causes the beam to rotate upwards by 90 to the vertica...