The 950 N automated system for leaf doors is an enbloc 

consisting of an electromechanical device that allows door 

opening by means of a transmission arm. The door closes 

itself using a spring system.

The operator can be installed either on the architrave or 

directly on the door structure.

The protective housing contains the electronic control unit 

for system programming and operation control. The 950 N 

operator is a reversible operator. Therefore, in the event of 

power drop, the door can be opened manually.

   This instruction is valid for firmware 

version 2.2 or later.

Automated system 

power supply

230 V~* or 115 V~* 

(+6% -10%) 

(* Depending on the model)

Absorbed power

100 W

Absorbed current

0,5 A

Electric motor

24 V=       with encoder

Dimensions

530 x 105 x 160

L x H x D

Weight

10 Kg

Operating ambient 

temperature

- 20° C..........+55°C

Protection  

class

IP 23 (indoor use)

Maximum leaf 

dimensions and 

weight

Section 3

Use frequency

continuous

ROT

Continuous use at 55°C

Operation with

no power

manual push or pull opening 

depending on the arm

Type of transmis-

sion arms

• 

Articulated

• 

Sliding L=330 mm

• 

Sliding L=430 mm

Anti-crushing 

device

With reverse in case of obstacle 

(standard supply)

Maximum 

opening angle

Section 3.3

950 N

2  DESCRIPTION AND TECHNICAL SPECIFICA-

TIONS

Opening 

time

adjustable 

from 4 to 10 seconds

Closing

time

adjustable

from 4 to 10 seconds

Accessories power 

Electric 

lock power supply

24 V 

=

1000mA max

Operating modes 

(by selector switch)

Open - Automatic - 

Manual or Night

Pause time

adjustable

from 0 to 30 seconds

Modes adjustable

With trimmer: see figure 5 

With dip switch: see figures 4 

and 6

Terminal board 

outputs

• 

Board fault signal

• 

Electric lock activation

• 

Accessories power supply

• 

Door status signal

• 

Exchange relay controlled 

from card reader

• 

2-leaf connection signal

• 

Signal for interlock between 

two doors

Terminal board 

inputs

• 

Opening commands

• 

Emergency command

• 

Key command

• 

Card reader command

• 

Fire protection command

• 

Opening STOP safety 

device with re-opening on 

release

• 

Safety device with inversion 

during closure

Rapid connectors

• 

KP controller/SDK light  

(optional)

• 

Radio rp, minidec, decoder 

board connector

• 

Mode selector switch  

connector

Mode selection

• 

Mode selector switch

• 

KP controller

• 

SDK light

1  PRELIMINARY CHECKS

For correct operation of the automated system, the existing door structure must feature the following:

1.  Length and weight corresponding to the description contained in section 3.1
2.  Max. post depth corresponding to the description contained in section 3.2
3.  Sturdy and rigid leaf structure.
4.  Existing hinges in good condition.
5.  Smooth and even movement of the leaf, without irregular friction during the entire stroke.
6.  Door “neutral” position during the entire stroke. Should the door tend to close or open, check the alignment of the hinges.
7.  Presence of mechanical limit switches or others integrated in the automated system being used.

Summary of Contents for 950N

Page 1: ...950 N EN 16005...

Page 2: ...950N 1 732708 Rev F BRACCIO ARTICOLATO ARTICULATED ARM BRAS ARTICUL BRAZO ARTICULADO GELENKARM KNIKARM LEDAD ARM a a b c d e f f h a g a c c a OPEN OPEN...

Page 3: ...se the optional extensions dimension with 50 mm shaft 87 mm with 80 mm shaft 117 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et le bras utiliser...

Page 4: ...elle 20 mm Wenn der Abstand zwischen dem Antrieb und dem Arm erh ht werden muss die optionalen Verl ngerungen verwenden Ma mit 50 mm Welle 87 mm Ma mit 80 mm Welle 117 mm Afstand met standaardas 20 mm...

Page 5: ...950N 4 732708 Rev F BRACCIO A PATTINO SLIDING ARM BRAS PATIN BRAZO DE PAT N GLEITKUFENARM ARM MET GLIJSCHOEN GLIDARM a a b e d d f f g i h j k OPEN...

Page 6: ...tor and the arm use the optional extensions dimension with 50 mm shaft 107 mm with 80 mm shaft 137 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et...

Page 7: ...he arm use the optional extensions dimension with 50 mm shaft 107 mm with 80 mm shaft 137 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et le bras...

Page 8: ...n en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO ARTICOLATO B 0 mm ARTICULATED PUSH ARM B 0 mm BRAS ARTICUL POUSS...

Page 9: ...eid openen en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 430 mm CON MONTAGGIO OPERATORE SULL ARCHITRA...

Page 10: ...uiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 330 mm CON MONTAGGIO OPERATORE SULL ARCHITRAVE B 160mm SLIDI...

Page 11: ...n en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 330 mm CON MONTAGGIO OPERATORE SULL ARCHITRAVE B 00mm...

Page 12: ...echnical documentation is compiled in accordance with part B of Annex VII of the above mentioned Machinery Directive The above identified partly completed machinery is also in compliance with the all...

Page 13: ...m 4 to 10 seconds Accessories power supply Electric lock power supply 24 V 1000mA max Operating modes by selector switch Open Automatic Manual or Night Pause time adjustable from 0 to 30 seconds Modes...

Page 14: ...0or 80 mm optional 3 APPLICATION LIMITS LEAF LENGTH mm MAX LEAF WEIGHT Kg ARTICULA TED PUSH ARM SLIDING ARM L 330 mm SLIDING ARM L 430 mm 700 367 286 750 320 249 800 281 219 850 249 194 900 222 173 95...

Page 15: ...emplates 4 2 INSTALLING THE TRANSMISSION ARMS It is always advisable to adjust the mechanical stops inside the opening closing operator so that they are occupied when the leaf reaches its mechanical s...

Page 16: ...programming unit optional 6 KP CONTROLLER locking key switch optional 7 Electric lock 24V max 0 5 A 8 Shunt box In case of operator on door installation make all electrical connections using a shunt b...

Page 17: ...is enabled the motor will not prevent manual opening 7 Not used 8 SCP Selectable Close Powe ring Additional force before closing NOTE With dip switch 9 set to OFF this function is never active Disable...

Page 18: ...rogress Slow flashing active fault LD3 Green LED for 5 V power supply 950 MPS BOARD TRIMMERS TR 1 Opening time adjustment 4 10 seconds TR 2 Closing time adjustment 4 10 seconds TR 3 Pause time adjustm...

Page 19: ...afety occupied Signals the status of input 14 LD8 Key command active Key command not active Signals the status of input 15 LD9 Fire prevention command active Fire prevention command not active Signals...

Page 20: ...pen it commands door closing the mode can be modified using the KP controller 13 Safety command during closing phase normally closed contact If open during closing it reverses the opening motion As lo...

Page 21: ...OPEN COMMAND n o EMERGENCY COMMAND n c SAFETY COMMAND DURING CLOSING n c STOP COMMAND DURING OPENING n c KEY COMMAND n o FIRE PREVENTION COMMAND n o CARD READER COMMAND GND GND 8 950 I 0 BOARD ELECTRI...

Page 22: ...70 1 XPB90 1 90 2 8 2 OPENING SAFETY SENSOR CONNECTION SET DIP 1 OF THE SENSOR TO ON 8 2 CLOSING SAFETY SENSOR CONNECTION Fig 9a Fig 9b IMPORTANT If this sensor is not present ter minal 13 must be con...

Page 23: ...ASSEMBLE THE SENSORS ON BOTH SIDES OF THE DOOR 2 ON THE CLOSING SAFETY SENSOR SET DIP 1 TO OFF 3 ON THE OPENING SAFETY SENSOR SET DIP 1 TO ON 4 CONNECT THE MASTER SENSOR TO THE SLAVE SENSOR VIA THE RE...

Page 24: ...950N 23 732708 Rev F J5 J4 950 I 0 J5 J4 ENGLISH ELECTROMAGNET 24V 8 4 ELECTROMAGNET COMMAND OUTPUT Fig 11 N C ELECTRIC LOCK 24 V 8 3 ELECTRICAL LOCK COMMAND OUTPUT N O Fig 10...

Page 25: ...ACT It closes when an automated system fault is active 8 5 DOOR STATUS OUTPUT Max contact capacity 0 5 A 24 V 8 6 BOARD FAULT OUTPUT Max contact capacity 0 5 A 24 V Fig 12 Fig 13 CARD READER INPUT N C...

Page 26: ...ator 4 Ensure that green LEDs LD1 and LD3 on the 950 MPS board are ON 5 Ensure that the status LEDs on the 950 I O board are in default status as shown in the table in figure 6 6 Perform a SET UP cycl...

Page 27: ...een two doors and the gong cannot be activated In a master and slave application all the sensor connections contacts test etc must be brought to the board set as master 12 LOW ENERGY dip switch 9 OFF...

Page 28: ...950N 27 732708 Rev F 530 107 121 mm ENGLISH 12 2 ASSEMBLINGTHEALUMINIUMHOUSING 4x TCI M5 x 10 FIXING SCREWS Fig 19...

Page 29: ...S Selection is done by pressing the keys located on the fixed section of the programmer the mode is identified by the lighting of the corresponding LED Note once the Night or Manual modes have been se...

Page 30: ...ac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 8713440 www faac ch CHINA FAAC SHANGHAI Shanghai China...

Reviews: