950N 18
732708
- Rev. F
950 I/0
F1= 4A
ENGLISH
7 PROGRAMMING AND DESCRIPTION OF THE 950 I/O BOARD
950 I/O BOARD LEDs
LED
ON
OFF
NOTE
LD1
Accessories power present
No accessories power
LD2
Card reader active
Card reader not active
Signals the status of
input 17
LD3
Internal opening command active
Internal opening sensor
not active
Signals the status of
input 10
LD4
External opening command active
External opening sensor
not active
Signals the status of
input 11
LD5
Emergency command not active
Emergency command active
Signals the status of
input 12
LD6
The opening STOP safety sensor is
not engaged
STOP safety active
Signals the status of
input 13
LD7
The closing safety sensor is not
engaged
Closing phase safety
occupied
Signals the status of
input 14
LD8
Key command active
Key command not active
Signals the status of
input 15
LD9
Fire-prevention command active
Fire-prevention command not
active
Signals the status of
input 16
BOLD PRINT INDICATES THE DEFAULT CONDITION WITH DOOR IN REST POSITION
SW1= SET-UP START BUTTON
950 I/O DS1 SETTING
N°
FUNCTION
OFF
ON
1
Pause time following ope-
ning using the “push and
go” function.
2
seconds
Value set in automatic mode (using TR3 or
KP controller trimmers)
2
Opening delay for door
with electric lock
200 milliseconds
(the electric lock re-
mains active up to a 70°
opening)
500 milliseconds
(the electric lock remains active for over a 70°
opening)
Inversion stroke starting from a closed position.
J7 = COUPLING FOR RADIO RECEI-
VER (RP, MINIDEC, DECODER)
J10 = 950 MPS POWER CONNECTOR
J11 = RAPID CONNECTOR FOR STATUS
SIGNALS TO THE 950 MPS BOARD
Fig.6
J9 = MOTOR POWER INTERRUP-
TION TERMINAL
Summary of Contents for 950N
Page 1: ...950 N EN 16005...