background image

950N 25 

 

732708

 - Rev. F

950 I/0

ENGLISH

SELECTOR 

 POSITION

MODE

DESCRIPTION

1

0

2

DOOR OPEN

When this mode is selected, the door opens and stays open.

1

0

2

AUTOMATIC

When this mode is selected, and when an internal/external command is acti-

vated, the door will open and close again after the pause time.

1

0

2

DIP N° 3 OFF

MANUAL

The door can be opened manually (the lock, if present, will remain inactive)

1

0

2

DIP N°3 ON

NIGHT

The external and internal commands are inactive. Door opening can be com-

manded only by activating the Key command.

   If the kp controller or sdk light is used, the selector switch will have no effect on the automated 

system.

10 OPERATION

Make the electrical connections on the 950 I/O control board 

as shown in section 8, connect the electrical mains supply 

to the corresponding terminal (fig.l-ref.

 j

 ) and ensure that 

the earthing cable is crimped to the terminal (fig.1-ref. 

) screwed on to the support profile (fig.l-ref. 

b

 ). Finally, 

tighten the terminal (fig.l-ref. 

)

Set the trimmer (see fig.5) and program the micro-switches 

(see fig.4 and 6) depending on need. To access the 

equipment, run the cables through the provided conduit 

(fig.l-ref. 

) or open the tabs on the sides of the housing.

   IMPORTANT:  When installing a sliding 

arm or for opening greater than 90° , before 

powering the system, set micro-switch nr. 

2 of the 950 MPS to ON.

2) Place the door in close position.

3) Power the operator.

4) Ensure that green LEDs LD1 and LD3 on the 950 MPS 

board are ON.

5) Ensure that the status LEDs on the 950 I/O board are in 

default status, as shown in the table in figure 6.

6) Perform a SET-UP cycle, as described in paragraph 10

10.1 SET-UP  PROCEDURE

  It is advisable to repeat the set-up 

procedure after having modified the 

opening and closing speed.

With the automated system powered, press SW1 (950 I/0)  

for at least 5 sec. until the red LED LD2 located on the 950 

MPS board is ON. The LED will begin flashing indicating 

that the SET UP procedure is in progress. During this 

procedure the following parameters are adjusted:

- door mass measurement;

- identification of the limit switch positions;

The door will open at reduced speed and will close 

approximately half way and then reverse to opening.

Closing is determined by the spring return action.

The process is inhibited in one of the following conditions:

1.  Mode selector switch in position 2 (MANUAL/NIGHT) or 

KP-CONTROLLER programmer in  MANUAL or NIGHT 

position

2.  Accessories connected incorrectly (electric lock, command/

safety elements);

3.  Incorrect position of the programming unit micro-switches.

  To repeat the set-up process, press SW1 for 

more than 5 seconds. Once the procedure is completed, 

ensure that the door opens and closes correctly.

  If a KP controller is used, the procedure can be 

performed directly from it.

The 950N operator features a 3-position mode selector switch (0-1-2) located on the side of the housing. The selector 

switch must be set on a mode. The connection cable to the 950 I/O must be positioned so as to avoid damaging it.

Summary of Contents for 950N

Page 1: ...950 N EN 16005...

Page 2: ...950N 1 732708 Rev F BRACCIO ARTICOLATO ARTICULATED ARM BRAS ARTICUL BRAZO ARTICULADO GELENKARM KNIKARM LEDAD ARM a a b c d e f f h a g a c c a OPEN OPEN...

Page 3: ...se the optional extensions dimension with 50 mm shaft 87 mm with 80 mm shaft 117 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et le bras utiliser...

Page 4: ...elle 20 mm Wenn der Abstand zwischen dem Antrieb und dem Arm erh ht werden muss die optionalen Verl ngerungen verwenden Ma mit 50 mm Welle 87 mm Ma mit 80 mm Welle 117 mm Afstand met standaardas 20 mm...

Page 5: ...950N 4 732708 Rev F BRACCIO A PATTINO SLIDING ARM BRAS PATIN BRAZO DE PAT N GLEITKUFENARM ARM MET GLIJSCHOEN GLIDARM a a b e d d f f g i h j k OPEN...

Page 6: ...tor and the arm use the optional extensions dimension with 50 mm shaft 107 mm with 80 mm shaft 137 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et...

Page 7: ...he arm use the optional extensions dimension with 50 mm shaft 107 mm with 80 mm shaft 137 mm Cote avec arbre standard de 20 mm S il est n cessaire d augmenter la distance entre l op rateur et le bras...

Page 8: ...n en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO ARTICOLATO B 0 mm ARTICULATED PUSH ARM B 0 mm BRAS ARTICUL POUSS...

Page 9: ...eid openen en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 430 mm CON MONTAGGIO OPERATORE SULL ARCHITRA...

Page 10: ...uiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 330 mm CON MONTAGGIO OPERATORE SULL ARCHITRAVE B 160mm SLIDI...

Page 11: ...n en sluiten in te stellen via KP CONTROLLER ppnings och st ngningshastighet st lls in med programmeringsenheten KP CONTROLLER BRACCIO A PATTINO L 330 mm CON MONTAGGIO OPERATORE SULL ARCHITRAVE B 00mm...

Page 12: ...echnical documentation is compiled in accordance with part B of Annex VII of the above mentioned Machinery Directive The above identified partly completed machinery is also in compliance with the all...

Page 13: ...m 4 to 10 seconds Accessories power supply Electric lock power supply 24 V 1000mA max Operating modes by selector switch Open Automatic Manual or Night Pause time adjustable from 0 to 30 seconds Modes...

Page 14: ...0or 80 mm optional 3 APPLICATION LIMITS LEAF LENGTH mm MAX LEAF WEIGHT Kg ARTICULA TED PUSH ARM SLIDING ARM L 330 mm SLIDING ARM L 430 mm 700 367 286 750 320 249 800 281 219 850 249 194 900 222 173 95...

Page 15: ...emplates 4 2 INSTALLING THE TRANSMISSION ARMS It is always advisable to adjust the mechanical stops inside the opening closing operator so that they are occupied when the leaf reaches its mechanical s...

Page 16: ...programming unit optional 6 KP CONTROLLER locking key switch optional 7 Electric lock 24V max 0 5 A 8 Shunt box In case of operator on door installation make all electrical connections using a shunt b...

Page 17: ...is enabled the motor will not prevent manual opening 7 Not used 8 SCP Selectable Close Powe ring Additional force before closing NOTE With dip switch 9 set to OFF this function is never active Disable...

Page 18: ...rogress Slow flashing active fault LD3 Green LED for 5 V power supply 950 MPS BOARD TRIMMERS TR 1 Opening time adjustment 4 10 seconds TR 2 Closing time adjustment 4 10 seconds TR 3 Pause time adjustm...

Page 19: ...afety occupied Signals the status of input 14 LD8 Key command active Key command not active Signals the status of input 15 LD9 Fire prevention command active Fire prevention command not active Signals...

Page 20: ...pen it commands door closing the mode can be modified using the KP controller 13 Safety command during closing phase normally closed contact If open during closing it reverses the opening motion As lo...

Page 21: ...OPEN COMMAND n o EMERGENCY COMMAND n c SAFETY COMMAND DURING CLOSING n c STOP COMMAND DURING OPENING n c KEY COMMAND n o FIRE PREVENTION COMMAND n o CARD READER COMMAND GND GND 8 950 I 0 BOARD ELECTRI...

Page 22: ...70 1 XPB90 1 90 2 8 2 OPENING SAFETY SENSOR CONNECTION SET DIP 1 OF THE SENSOR TO ON 8 2 CLOSING SAFETY SENSOR CONNECTION Fig 9a Fig 9b IMPORTANT If this sensor is not present ter minal 13 must be con...

Page 23: ...ASSEMBLE THE SENSORS ON BOTH SIDES OF THE DOOR 2 ON THE CLOSING SAFETY SENSOR SET DIP 1 TO OFF 3 ON THE OPENING SAFETY SENSOR SET DIP 1 TO ON 4 CONNECT THE MASTER SENSOR TO THE SLAVE SENSOR VIA THE RE...

Page 24: ...950N 23 732708 Rev F J5 J4 950 I 0 J5 J4 ENGLISH ELECTROMAGNET 24V 8 4 ELECTROMAGNET COMMAND OUTPUT Fig 11 N C ELECTRIC LOCK 24 V 8 3 ELECTRICAL LOCK COMMAND OUTPUT N O Fig 10...

Page 25: ...ACT It closes when an automated system fault is active 8 5 DOOR STATUS OUTPUT Max contact capacity 0 5 A 24 V 8 6 BOARD FAULT OUTPUT Max contact capacity 0 5 A 24 V Fig 12 Fig 13 CARD READER INPUT N C...

Page 26: ...ator 4 Ensure that green LEDs LD1 and LD3 on the 950 MPS board are ON 5 Ensure that the status LEDs on the 950 I O board are in default status as shown in the table in figure 6 6 Perform a SET UP cycl...

Page 27: ...een two doors and the gong cannot be activated In a master and slave application all the sensor connections contacts test etc must be brought to the board set as master 12 LOW ENERGY dip switch 9 OFF...

Page 28: ...950N 27 732708 Rev F 530 107 121 mm ENGLISH 12 2 ASSEMBLINGTHEALUMINIUMHOUSING 4x TCI M5 x 10 FIXING SCREWS Fig 19...

Page 29: ...S Selection is done by pressing the keys located on the fixed section of the programmer the mode is identified by the lighting of the corresponding LED Note once the Night or Manual modes have been se...

Page 30: ...ac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 8713440 www faac ch CHINA FAAC SHANGHAI Shanghai China...

Reviews: