950N 25
732708
- Rev. F
950 I/0
ENGLISH
SELECTOR
POSITION
MODE
DESCRIPTION
1
0
2
DOOR OPEN
When this mode is selected, the door opens and stays open.
1
0
2
AUTOMATIC
When this mode is selected, and when an internal/external command is acti-
vated, the door will open and close again after the pause time.
1
0
2
DIP N° 3 OFF
MANUAL
The door can be opened manually (the lock, if present, will remain inactive)
1
0
2
DIP N°3 ON
NIGHT
The external and internal commands are inactive. Door opening can be com-
manded only by activating the Key command.
If the kp controller or sdk light is used, the selector switch will have no effect on the automated
system.
10 OPERATION
Make the electrical connections on the 950 I/O control board
as shown in section 8, connect the electrical mains supply
to the corresponding terminal (fig.l-ref.
j
) and ensure that
the earthing cable is crimped to the terminal (fig.1-ref.
l
) screwed on to the support profile (fig.l-ref.
b
). Finally,
tighten the terminal (fig.l-ref.
m
)
Set the trimmer (see fig.5) and program the micro-switches
(see fig.4 and 6) depending on need. To access the
equipment, run the cables through the provided conduit
(fig.l-ref.
a
) or open the tabs on the sides of the housing.
IMPORTANT: When installing a sliding
arm or for opening greater than 90° , before
powering the system, set micro-switch nr.
2 of the 950 MPS to ON.
2) Place the door in close position.
3) Power the operator.
4) Ensure that green LEDs LD1 and LD3 on the 950 MPS
board are ON.
5) Ensure that the status LEDs on the 950 I/O board are in
default status, as shown in the table in figure 6.
6) Perform a SET-UP cycle, as described in paragraph 10
10.1 SET-UP PROCEDURE
It is advisable to repeat the set-up
procedure after having modified the
opening and closing speed.
With the automated system powered, press SW1 (950 I/0)
for at least 5 sec. until the red LED LD2 located on the 950
MPS board is ON. The LED will begin flashing indicating
that the SET UP procedure is in progress. During this
procedure the following parameters are adjusted:
- door mass measurement;
- identification of the limit switch positions;
The door will open at reduced speed and will close
approximately half way and then reverse to opening.
Closing is determined by the spring return action.
The process is inhibited in one of the following conditions:
1. Mode selector switch in position 2 (MANUAL/NIGHT) or
KP-CONTROLLER programmer in MANUAL or NIGHT
position
2. Accessories connected incorrectly (electric lock, command/
safety elements);
3. Incorrect position of the programming unit micro-switches.
To repeat the set-up process, press SW1 for
more than 5 seconds. Once the procedure is completed,
ensure that the door opens and closes correctly.
If a KP controller is used, the procedure can be
performed directly from it.
The 950N operator features a 3-position mode selector switch (0-1-2) located on the side of the housing. The selector
switch must be set on a mode. The connection cable to the 950 I/O must be positioned so as to avoid damaging it.
Summary of Contents for 950N
Page 1: ...950 N EN 16005...