A1400 AIR RDT
111
532119 04 - Rev. C
1
OPERATOR’S GUIDE
USE
Systems FAAC series A1400 AIR RDT make it possible to operate auto-
matically, manage and control operation of sliding one- or two-leaf
doors, with linear horizontal motion.
The automations of series A1400 AIR RDT are designed to install
automated entry doors exclusively for pedestrian traffic.
They are suitable for installing emergency exits compliant with
standard EN 16005:2012.
They are suitable for indoor installation, for applications meeting the
features detailed in the instruction manual.
!
No other use outside the ones set out above is allowed by the
manufacturer.
FAAC disclaims all liability deriving from misuse or use other than that
for which the automation is intended.
Unauthorised use
-
use the automation for uses other than THE INTENDED USE;
-
use the automation with mobile and fixed guards tampered
with or removed.
-
WARNINGS DURING NORMAL OPERATION
The following conditions can occur during normal operation of the
door:
The door A1400 AIR RDT runs a system test in 24h: the door opens
and closes.
A system test is immediately run when changing from NIGHT-TIME or
MANUAL mode to
TWO-DIRECTION AUTOMATIC
mode
If there is a power outage, the door opens and remains open. The
door closes again only when the power is restored.
If the battery is flat, even with power, the door opens and remains
open. The door open status for this problem alerted with an acoustic
signal with 4 s intervals.
MANUAL OPERATION
Release manoeuvre
If it is necessary to manually actuate the internal release to manually
open the door, proceed as follows:
To open the door pull the red knob downwards and turn it anti-
clockwise until it locks on the bracket Fig. 1.
To close the door pull the red knob downwards to release it and turn
it clockwise until it locks on the bracket Fig. 1.
RECOMMENDATIONS FOR SAFETY OF THE ESCAPE ROUTES
The automation A1400 AIR RDT, created for escape routes, if correctly
installed, maintained and used, guarantees a high level of safety.
!
Selection of NIGHT-TIME or MANUAL mode will lose operation of
door A1400 AIR RDT for the escape routes. The operator must verify
that there is no one inside the rooms before activating these modes.
GENERAL SAFETY RECOMMENDATIONS
The operator in charge of using the automation is responsible for
running the system and must:
!
carefully read the instructions before using the product and store
them for future use
comply with all Operating instructions and Safety recommendations
store the instructions of the products installed
prevent the control devices from being used by persons not expressly
authorised and instructed
prevent access to the control devices to persons under age or with
reduced psycho-physical abilities, unless under supervision by an
adult responsible for their safety
not use the system in case of malfunctioning. In the event of mal-
functioning, the operator must abstain from any attempt to repair or
intervene directly. He/she must request intervention by the installer/
maintenance technician.
make sure the system’s maintenance is carried out according to the
instructions provided in this manual.
must be in good psycho-physical conditions, aware of and responsible
about the hazards that may be engendered when using a machine.
the required level of ambient lighting must be equal to at least 200 lux
store the system Register filled in at the end of every maintenance
operation by the installer/maintenance technician
Routine and planned maintenance
!
To maintain safety conditions and operating efficiency and reduce
faults and disservice, ROUTINE MAINTENANCE and PERIODIC REPLACE-
MENTS set out in manual A1400 AIR RDT must be carried out.
All maintenance operations must exclusively be performed by
technical-professional personnel.
Only the installer/maintenance technician is authorised to open the
casing to access the automation housing.
ROUTINE MAINTENANCE must be performed every 6 months.
Frequency of REPLACEMENTS is indicated based on number of opera-
tion cycles for components subject to wear; in years for components
subject to deterioration.
The acoustic signal alerts to the need to perform planned
replacements.