A1400 AIR RDT
12
532119 04 - Rev. C
1
230V~
6
1
2
5
4
3
7
7
Tr
ansla
tion of the original instruc
tions
ENGLISH
2. AUTOMATION A1400 AIR RDT
2.1 INTENDED USE
Systems FAAC series A1400 AIR RDT make it possible to operate auto-
matically, manage and control operation of sliding one- or two-leaf
doors, with linear horizontal motion.
The automations of series A1400 AIR RDT are designed to install
automated entry doors exclusively for pedestrian traffic.
They are suitable for installing emergency exits compliant with
standard EN 16005:2012.
They are suitable for indoor installation, for applications meeting the
features detailed in
7
.
!
No other use outside the ones set out above is allowed by the
manufacturer.
FAAC disclaims all liability deriving from misuse or use other than that
for which the automation is intended.
LIMITATIONS FOR USE
Do not use the automation in the presence of the following conditions:
-
direct exposure to weathering
-
exposure to direct water jets of any type or extent
-
outside the technical limitations set out. Specifically, it is forbid-
den to connect to sources of energy other than those set out.
2.2 UNAUTHORISED USE
It is forbidden to:
-
use the automation for uses other than THE INTENDED USE;
-
use the automation for installing smoke and/or fire protection
doors (fire doors);
-
install integral anti-panic breakout systems (APN) on doors series
A1400 AIR RDT;
-
use the automation with mobile and fixed guards tampered
with or removed;
-
use the automation in premises under risk of explosion and/or
fire: the presence of flammable gases or fumes is a severe danger
for safety (the product is not certified pursuant to the 94/9/EC
ATEX directive);
-
integrate other systems and/or commercial equipment not
intended;
-
use other systems and/or commercial equipment for uses not
authorised by the respective manufacturers;
-
use commercial devices for purposes other than those set out by
the respective manufacturers.
external
internal
1
Monitored detector for internal opening and safe closing (XDT3)
included in the supply
2
Monitored detector for external opening and safe closing (XV1/XDT1)
optional accessory
3
SDK EVO
optional accessory
4
Key switch to lock theSDK EVO
optional accessory
5
Emergency/Key/OPEN control buttons
optional accessories
6
Power supply 230V~
7 Internal monitored detectors for safe opening (XBFA)
optional accessory