MOTOR RELEASE MONITOR XB LOCK
(OPTIONAL ACCESSORY)
Install the micro switch on the motor block
12
.
INTERNAL RELEASE
The knob must be unscrewed and removed to open the automation
casing after mounting the internal release.
1. Screw the adjustment, with the relevant locking nut
13
-
.
2. Extract about 20 cm steel cable from the sheath. Insert the cable in
the adjustment screw and run it into the release device
13
-
.
3. Tighten the screw
13
-
to lock the steel cable.
4. Move the black cable sheath against the adjustment screw and
screw the adjustment screw fully into the bracket.
5. Insert two plates into the profile
14
-
and fit the release knob
into the side bracket.
6. Lock the knob: pull it and turn it by 90°
13
. The knob must
maintain this position.
7. Run the cable with sheath into the suitable cable ducts up to the
motor block. Avoid bending the sheath too tightly.
8. Move the cable with sheath close to part
in
15
and remove
the excess sheath.
9. Run the cable into the guide
15
-
so the sheath is in contact.
Insert the cable in the clamp
.
10. Pull the block
all the way, compressing the springs. Tighten the
clamp screw
to lock the steel cable.
11. Cut the excess steel cable.
MOTOR BLOCK OPERATION TEST XB LOCK
The motor must be unhindered: motor block not inserted in the motor
shaft coupling.
-
To adjust cable tension, act on the adjustment screw
13
-
.
-
Unlock the knob by turning it 90° and ensure the release is working.
-
Pull the knob to ensure the door opening micro switch is activated
15
-
).
If installation of the external release is required, use suitable key but-
tons. Insert the release cable in the suitable housing in the motor block.