13.2 BASIC / ADVANCED PROGRAMMING
BASIC programming (see
11
)
1. Press F until the first basic function is displayed.
3 s
0.0
RESET/SETUP
DL2
+
-
F
J
Ln
Ln
F
The function code remains displayed as long as it is pressed
2. Release F. The default value is displayed (or other programmed
one)
0.0
RESET/SETUP
DL2
+
-
F
J
Ln
Ln
2
2
3. Use b or
-
to modify the value of a function
4. Press F to confirm the displayed value. Move to the next func-
tion. The modified value becomes effective immediately. Pro-
ceed in the same way for all functions. The last (
St
St
) closes
programming.
5. In
St
St
select
Y
Y
or
no
no
with b/
-
:
-
Y
Y
= save new programming
-
no
no
= does NOT save new programming
0.0
RESET/SETUP
DL2
+
-
F
J25
+
/
-
Y
Y
Y
Y
/
no
no
6. Press F to confirm and close. Go back to automation status (
14
).
0.0
RESET/SETUP
DL2
+
-
F
J2
02
02
(example)
F
Advanced Programming (see
12
)
1. Press and hold F and + as well, until the first advanced function
is displayed.
0.0
RESET/SETUP
DL2
+
-
F
J
P1
P1
+
F
The function code remains displayed as long as it is pressed
2. Release F and +. The default value is displayed (or other pro-
grammed one)
0.0
RESET/SETUP
DL2
+
-
F
J
P1
P1
Cc
Cc
3. Use b or
-
to modify the value of a function
4. Press F to confirm the displayed value. Move to the next func-
tion. The modified value becomes effective immediately. Pro-
ceed in the same way for all functions. The last (
St
St
) closes
programming.
5. In
St
St
select
Y
Y
or
no
no
with b/
-
:
-
Y
Y
= save new programming
-
no
no
= does NOT save new programming
0.0
RESET/SETUP
DL2
+
-
F
J
+
/
-
Y
Y
Y
Y
/
no
no
6. Press F to confirm and close. Go back to automation status (
14
).
0.0
RESET/SETUP
DL2
+
-
F
J2
02
02
(example)
F
Programming time expiration
Programming is interrupted after 10 minutes of inactivity on b,
-
, F. The display goes back to automation status and UNSAVED modifications
must be performed again.
Power failure during programming
If power supply fails while programming is ongoing, UNSAVED modifications must be performed again.
Immediately exit programming
During programming, press simultaneously F and
-
until programming exit is activated: function
St
St
.
0.0
RESET/SETUP
DL2
+
-
F
St
St
-
F