A1400 AIR RDT
66
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
ADVANCED Function
Default
P2
P2
SAFETY INPUT CONFIGURATION S2
no
no
= no device
Co
Co
= safety on closure with NO contact
Cc
Cc
= safety on closure with NC contact
Oo
Oo
= safety on opening with NO contact
Oc
Oc
= safety on opening with NC contact
no
no
(
*
)
2F
2F
SAFETY INPUT TEST S2
Not displayed if
P2
P2
=
no
no
YY
= test enabled
no
no
= test not enabled
Y
Y
P3
P3
SAFETY INPUT CONFIGURATION S3
no
no
= no device
Co
Co
= safety on closure with NO contact
Cc
Cc
= safety on closure with NC contact
Oo
Oo
= safety on opening with NO contact
Oc
Oc
= safety on opening with NC contact
Cc
Cc
(
*
)
3F
3F
SAFETY INPUT TEST S3
Not displayed if
P3
P3
=
no
no
YY
= test enabled
no
no
= test not enabled
Y
Y
P4
P4
SAFETY INPUT CONFIGURATION S4
no
no
= no device
Co
Co
= safety on closure with NO contact
Cc
Cc
= safety on closure with NC contact
Oo
Oo
= safety on opening with NO contact
Oc
Oc
= safety on opening with NC contact
Cc
Cc
(
*
)
4F
4F
SAFETY INPUT TEST S4
Not displayed if
P4
P4
=
no
no
YY
= test enabled
no
no
= test not enabled
Y
Y
Ot
Ot
OPERATION OF SAFETIES ON OPENING
1
1
=
STOP
2
2
= LOW ENERGY (motion slowed down)
On the escape route doors the safeties on
opening are considered only beyond the PO %
(partial opening) set. Any activations before
this point WILL NOT be considered.
2
2
bP
bP
BUTTON PHOTOCELLS (OPTIONAL)
no
no
= no photocell
1
1
= 1 pair of photocells
2
2
= 2 pairs of photocells
no
no
ADVANCED Function
Default
C1
C1
INPUT I1 CONFIGURATION
NO input
(
**
)
(
**
)
Programmable as NC with SDK EVO
0
0
= input not enabled
1
1
= Always Open
2
2
= OPEN external
3
3
= EXIT ONLY OPENING
4
4
= OPEN Automatic
5
5
= OPEN Semi-automatic
6
6
= PHARMACY OPENING
(only works in night-time mode paired with
PF
PF
)
7
7
= Key (opening in NIGHT-TIME mode)
16
16
= NIGHT-TIME mode**
17
17
= MANUAL mode **
(** )The choice of this configuration automatically implies
the same operation on I2 input.
Note : For specific functions of the inputs see § 14.2
04
04
PF
PF
PHARMACY OPENING
Only displayed if =
CI
CI
=
6
6
Adjustable from 5% to 95% (MAX) of complete opening
Step = 5%
The input configured as Pharmacy functions
in NIGHT-TIME mode; the other operating
modes are equivalent to an input configured
as AUTOMATIC OPEN
20
20
bn
bn
NIGHT-TIME BATTERY KIT
Operation of the battery in NIGHT-TIME mode with power
outage.
1
1
= immediately perform OPENING motion
2
2
= immediately perform CLOSING motion
3
3
= with flat battery last OPENING motion
4
4
= with flat battery last CLOSING motion
4
4
EL
EL
MOTOR BLOCK_1 (OPTIONAL)
74
rif .C
no
no
= not enabled
1
1
= motor block XB LOCK closed in NIGHT-TIME mode
2
2
= motor block XB LOCK closed in NIGHT-TIME mode and OPEN
3
3
= motor block XM LOCK closed in NIGHT-TIME mode
4
4
= motor block XM LOCK closed in NIGHT-TIME and OPEN
no
no
SU
SU
MONITORING on MOTOR BLOCK
XB LOCK / XM LOCK
Not displayed if
EL
EL
=
no
no
no
no
= not enabled
Y
Y
= enabled
no
no
nd
nd
NIGHT-TIME MODE DELAY
When night-time mode is set, the internal detector remains
active for the time set with this function to allow one open-
ing only. The internal detector is disabled immediately after
opening and in any case upon expiry of the set delay.
Adjustable from
0
0
to
60
60
s
Step = 1 s
10
10