14. SYSTEM FUNCTIONALITY/CONFIGURATIONS
14.1 OPERATING MODE
The following operating modes may be activated from SDK EVO :
Selection is carried out by pressing the keys on the fixed part of the
programmer; the function is identified by the corresponding symbol
switching on.
-
NIGHT
The door closes and motor block is activated (if present). The internal
and external radar are disabled.
The Key control causes opening and closing again after the night-
time pause time.
-
MANUAL
The sliding leaves are free and may be manually operated.
The door does NOT operate as an escape route in NIGHT-TIME and
MANUAL modes.
-
AUTOMATIC
The door opens (partially or totally) then closes again after the set
pause time (default 2 sec.).
Pause time adjustment from 0 to 30 sec.
-
DOOR OPEN
The door opens and remains open.
-
TWO-DIRECTION AUTOMATIC
Pedestrian transit occurs in both directions; the internal and external
radars are enabled.
-
ONE-DIRECTION AUTOMATIC
Pedestrian transit occurs in one direction only; the external radar is
disabled.
-
TOTAL OPENING
100%
The door opens fully.
-
PARTIAL OPEN
%
The door performs reduced openings (default 20%).
Adjustment from 20% to 95% of total opening with 5% step.
Function
Door Status
Internal Sensor
External Sensor
KEY
Emergency
MANUAL
--------
no effect
no effect
no effect
no effect
TOTALLY OPEN
100%
OPEN
no effect
no effect
no effect
no effect
AUTOMATIC TWO-DIRECTIONAL
TOTAL
100%
OPEN
pause counting restarts
pause counting restarts
pause counting restarts
no effect
CLOSED
total opening and closure again
after pause time
total opening and closure again
after pause time
total opening and closure again
after pause time
total opening
AUTOMATIC TWO-DIRECTIONAL
PARTIAL
%
OPENING
PARTIAL
pause counting restarts
pause counting restarts
pause counting restarts
total opening
CLOSED
partial opening and closure again
after pause time
partial opening and closure again
after pause time
partial opening and closure again
after pause time
total opening
AUTOMATIC ONE-DIRECTIONAL
TOTAL (EXIT ONLY)
100%
OPEN
pause counting restarts
no effect
pause counting restarts
total opening
CLOSED
total opening and closure again
after pause time
no effect
total opening and closure again
after pause time
total opening
AUTOMATIC ONE-DIRECTIONAL
PARTIAL (EXIT ONLY)
%
OPENING
PARTIAL
pause counting restarts
no effect
pause counting restarts
total opening
CLOSED
partial opening and closure again
after pause time
no effect
partial opening and closure again
after pause time
total opening
NIGHT
CLOSED
no effect
no effect
total opening and closure again
after night pause time
total opening
PARTIAL NIGHT-TIME
%
CLOSED
no effect
no effect
partial opening and closure again
after night pause time
total opening
PARTIAL OPENING
%
OPEN
PARTIAL
no effect
no effect
no effect
no effect
Summary of Contents for A1400 AIR RD