A1400 AIR RDT
74
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
Error
Required action (perform RESET after the intervention)
1
1
Board
failure
Perform RESET. If the problem persists replace the control board.
2
2
Board
E
2
prom fault
Perform RESET. If the problem persists replace the control board.
3
3
Motor_1 Driver
failure
Perform RESET. If the problem persists replace the control board.
4
4
Faulty
accessories power supply
Perform RESET. If the problem persists replace the control board.
5
5
micro-controller
error
Update FW. The file on USB storage device is required (
78
)
6
6
Motor_1 power supply voltage
fault
Perform RESET. If the problem persists replace the control board.
7
7
Motor_1
faulty
Replace Motor_1.
8
8
Opening failed with
AUX_Motor
Perform RESET. If the problem persists replace the control board.
9
9
Mains power supply
(V main) absent*
The door performs opening with battery power supply and remains open in error (safety
condition)
Wait for the mains power supply to be restored
If the error persists despite mains power supply being on, replace the power supply unit.
10
10
Battery
down or NOT connected*
If the battery is down or disconnected, the door performs opening and remains open in error.
Check battery status and connection. If the battery is completely drained, the charging cycle
requires several hours. Perform reset.
11
11
S1
test failed
Check that:
- connection of the safety device.
- operation of the safety device.
- input programming
P1
P1
-
P2
P2
-
P3
P3
-
P4
P4
.
12
12
S2
test failed
13
13
S3
test failed
14
14
S4
test failed
15
15
Data in setup memory not present or corrupted
Perform SETUP.
16
16
Encoder
failure
Replace Motor_1.
17
17
Inputs
failure
Perform RESET. If the problem persists replace the control board.
18
18
Firmware
(FW) not compatible
During the update stage, an incorrect FW has been detected. Check and update again the
control board FW. The file on USB storage device is required (
78
).
19
19
High
mechanical friction
Check the leaves slide smoothly with power supply, battery and motors disconnected. Remove
any friction. Check the counter wheel.
20
20
Inputs
configured as safety devices test failed
Check input connection and programming.
21
21
Opening speed low
Modify speed programming:
OS
OS
function.
SDK EVO also allows the acceleration and deceleration ramps and slow down space to be
modified in opening.
A SETUP must then be performed.
22
22
Corrupted data
Perform board programming again, or upload programming files saved on USB memory
stick (
78
).
23
23
Power supply unit fault
Replace power supply unit
24
24
Consecutive obstacles in closing
Check for and remove the obstacle in closing. If the error persists with no obstacle check the
level of force in closing.
25
25
AUX_Motor
faulty
Replace Auxiliary_Motor.
26
26
Motor block fault
Replace motor block
27
27
Motor_1 rotation error
Check belt connection to the leaves.
28
28
AUX_Motor
rotation error
Check auxiliary_motor connection
29
29
_AUX board
fault
Replace the control board.
30
30
Serious error
(with continuous
buzzer
)
It is impossible to open with both motors. Set manual mode and manually open the leaves.
Request the installer's servicing.
31
31
Consecutive obstacles in opening
Check for and remove the obstacle in opening.
39
39
Board data being deleted
Restore procedure executed.
* When the condition is restored, this error disappears without requiring a RESET.