A1400 AIR RDT
75
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
16
Alerts
Indication
Intervention required
41
41
Date and time loss
Reset time and date with SDK EVO.
42
42
Clock battery
flat or absent
In case of mains power supply failure, replace the battery to avoid losing the time.
43
43
System test
System test in progress
44
44
Emergency
active
signal that an emergency is active
45
45
Timer
active
the TIMER is in activated state
46
46
Timer
Function in progress
A TIMER function is running with operating mode other than
Total Two-directional Automatic)
47
47
Last motion run with battery
The board has run the last motion programmed.
48
48
Night-time
mode operation
Night-time mode operation.
49
49
Manual
mode operation
Manual mode operation
50
50
Partial
mode operation
Partial mode operation
51
51
Obstacle in closure
detected
The door opens again. Check for an obstacle in closing
52
52
Obstacle in opening
detected
After 5 sec. the door attempts another opening.
Check for an obstacle in opening.
53
53
Number of maintenance cycles corrupted on
E
2
prom
Replace the control board and perform maintenance on the system.
54
54
Fault on
Motor_1 block driver
Perform RESET. Check the motor block
55
55
Operation in
pharmacy
mode in progress
PHARMACY opening is in progress.
56
56
Battery
operation
the indication remains as long as the automation operates on battery with mains power
supply down.
57
57
Searching for strike on opening
the indication remains as long as the stage is ongoing
58
58
Searching for strike on closing
the indication remains as long as the stage is ongoing
59
59
Motor block Anomaly (only with Monitoring Kit)
Perform RESET. If the problem persists replace the motor block.
60
60
Maintenance
requested
(with
acoustic signal
at 4 s intervals).
3 s
Have scheduled maintenance performed and reset the relevant cycle counter with SDK EVO.
61
61
Fault SDK EVO
o LKEVO
Check it is the correct device and check the connections SDK EVO or LKEVO.
Update FW (see procedure
78
).
If the problem persists, replace SDK EVO or LKEVO.
62
62
Faulty
battery charger
Perform RESET. If the problem persists replace the control board.
63
63
Intrusion in progress
An attempt to manually open the leaves is in progress
64
64
Last opening too slow, not compliant with EN16005
after 10 openings with this alert active, the system goes into error
21
21
65
65
SETUP in progress
SETUP is in progress.
66
66
The AUX board is moving the leaves
Opening with AUX board is in progress.
67
67
Battery saving
Power supply to the accessories of the board (Excluding SDK EVO or LKEVO) has been discon-
nected to save and avoid quick discharge of the battery.
68
68
Alarm on Test
Check detector operation. If the problem persists, replace the detector.
In this condition the leaves move at a slower speed.
69
69
Door open
the door is open for semi-automatic OPEN function.
70
70
Low batteries level
batteries charging
80
80
Programming other than standard
Alert not displayed by the board.
* When the condition is restored, this error disappears without requiring a RESET.
17
AUX Errors
AUX Errors
Intervention required
200
200
UC Failure (Corrupted FW or Corrupted RAM)
Carry out board reset; if the error persists replace the board.