10 Test Error
Enables/disables movement at slower speed in the event of TEST
ERROR on safety devices.
-
ENABLED
-
DISABLED
(Default)
■
9 LOG
OK
OK
LOG
2
PROGRAMMING
MENU NOT AVAILABLE
MENU 3 ERRORS
OK
OK
OK
OK
01 BOARD
FAULT
3
ERRORS
02.....................31
39 OBST. CONS.
OPENING
The display shows current errors:
-
1 Board Failure
-
2 Board E2PROM fault
-
3 Motor_1 driver failure
-
4 VACC anomaly
-
5 Micro-controller error
-
6 VMOT anomaly
-
7 MOT1 motor fault
-
8 AUX motor opening failed
-
9 Mains power supply V main absent
-
10 Battery down or not connected
-
11 S1 test failed
-
12 S2 test failed
-
13 S3 test failed
-
14 S4 test failed
-
15 Data in setup memory not present or corrupted
-
16 Encoder
fault
-
17 Inputs
fault
-
18 FW not compatible
-
19 High mechanical friction
-
20 Input configured as safety devices test failed
-
21 Low speed opening.
-
22 Corrupted
data
-
23 Power supply unit fault
-
24 Consecutive obstacles in closing
-
25 AUX_Motor
faulty
-
26 Motor block fault
-
27 Motor_1 rotation error
-
28 AUX_Motor rotation error
-
29 AUX+Motor board fault
-
30 Serious error
-
31 Consecutive obstacles in opening
-
39 Board data being deleted
OK
OK
OK
200 UC FAILURE
3
ERRORS
201...................221
222 TEST VMAIN
1 ERRORS
2 AUX ERRORS
OK
The display shows current errors:
-
200 UC Failure (Corrupted FW or Corrupted RAM)
-
201 Aux Mot Fault
-
202 High
Friction
-
203 Aux Mot Driver
-
204 FW Not Compatible
-
205 Motor
Rotation
-
206 Encoder
Fault
-
216 Communication
(Communication problem between the 2 boards)
-
217 Incorrect Opening Position
-
218 Obstacle
-
219 Incorrect
ID
-
220 Vmain
-
221 Timeout
-
222 Test
Vmain
MENU 4 INDICATIONS
OK
OK
OK
OK
41 TIME LOSS
4
WARNINGS
42.....................79
80 NON STANDARD
PROGRAM.
The display shows current alerts:
-
41 Date and time loss
-
42 Clock battery flat or absent
-
44 Emergency
active
-
45 TIMER
active
(indicated with
T
in HOME PAGE)
-
46 Timer function in progress
-
47 Last motion run with battery
-
48 Night-time mode operation
-
49 Manual mode operation
-
50 Partial mode operation
-
51 Obstacle in closing
-
52 Obstacle in opening
-
53 Number of maintenance cycles corrupted on E2prom
-
54 Motor block fault
-
55 Pharmacy mode operation
-
56 Battery
operation
-
57 Searching for strike on opening
-
58 Searching for strike on closing
-
59 Motor block anomaly (only with monitoring KIT)
-
60 Requested
maintenance
-
61 SDK EVO anomaly
-
62 Faulty battery charger