6.8 INPUTS CONFIGURATION (J4)
The inputs on terminal board J4 (I1-I4 and S1-S2) can
be configured on the A951 or via the KP EVO using the
following functions.
Each input can be set to NC or NO according to the
device connected to it.
■
DISABLED
No associated function.
■
EXTERNAL OPENING
When activated, the door opens and remains open as
long as the input is active. When released, the door
waits for the pause time to elapse and then closes.
This has no effect in the EXIT ONLY or NIGHT modes.
■
INTERNAL OPENING
When activated, the door opens and remains open as
long as the input is active. When released, the door
waits for the pause time to elapse and then closes.
This has no effect in the ONLY IN or NIGHT modes.
■
AUTOMATIC OPENING
When activated, the door opens and remains open as
long as the input is active. When released, the door
waits for the pause time to elapse and then closes.
Active in the BI-DIRECTIONAL, EXIT ONLY and ONLY
IN modes.
This has no effect in the NIGHT mode.
■
SEMI-AUTOMATIC OPENING
When activated:
-
if the door is not already open, it opens and re-
mains open
-
if the door is already open, it closes
Active in the BI-DIRECTIONAL, EXIT ONLY and ONLY
IN modes.
This has no effect in the NIGHT mode.
■
KEY
When activated, the door opens and remains open
as long as the input is active. When released, the
door waits for the night pause time to elapse and
then closes.
Active in the BI-DIRECTIONAL, EXIT ONLY, IN ONLY and
NIGHT modes.
■
PARTIAL OPEN
Only opens the master door when activated in the “2
leaves” mode.
■
CLOSING SAFETY DEVICE
When activated:
-
If the door is closing, it reopens.
-
If the door is already open, it prevents it from
closing.
-
If the door is opening, it has no effect.
■
OPENING SAFETY DEVICE
When activated:
-
If the door is opening, it stops until it is released.
-
If the door is already closed, it prevents it from
opening.
-
If the door is closing, it has no effect.
■
EMERGENCY OPENING
When activated, the door opens (always total) and
remains open as long as the input is active. When
released, the door waits for the night pause time to
elapse and then closes.
Also active in NIGHT mode.
■
EMERGENCY OPEN WITH MEMORY
When activated, the door opens (always total) and
remains open as long as the input is active. When
released, the door remains open until a system RESET
is carried out.
■
EMERGENCY CLOSING
When activated, the door closes and remains closed as
long as the input is active. When released, the door
returns to normal operation.
■
EMERGENCY CLOSE WITH MEMORY
When activated, the door closes and remains closed as
long as the input is active. When released, the door
remains closed until a system RESET is carried out.
■
ALWAYS OPEN
When activated, the ALWAYS OPEN mode is set.
■
EXIT ONLY
When activated, the EXIT ONLY mode is set.
■
ENTRY ONLY
When activated, the ONLY IN operating mode is set.
■
NIGHT
When activated, the NIGHT mode is set.
■
MANUAL
When activated, the MANUAL mode is set.
■
PARTIAL
When activated, the PARTIAL mode is set.
■
INTERBLOCK ON
When activated, the INTERLOCK mode is set.
■
TIMER
When activated, the TIMER mode is set.