A951
47
532081 - RevA
Tr
ansla
tion of the original instruc
tions
ENGLISH
PROGRAMMING
This menu includes all the operating parameters of
the A951. For those that are also available in the on
board programming, the corresponding function is
indicated in square brackets. For an explanation please
refer to
9
and
10
. Those that are not available
in on-board programming are explained below.
■
SLOWDOWN
Defines the space (in degrees of rotation of the A951
shaft and the slowdown speed (on 3 levels) of the
door before reaching the final open / closed positions.
■
ACCELERATION
Specifies how quickly the door reaches the set opening
speed when starting from stop.
Adjustable over 10 levels (10 = maximum accelera-
tion).
■
DECELERATION
Specifies how quickly the door stops.
Adjustable over 10 levels (10 = maximum deceler-
ation).
■
2 EASY REG.
Registration of
BUS 2easy
.
■
RELEASE TYPE
Specifies when power is disconnected from the lock
after it has been mechanically released.
-
OPENING = during the opening phase
-
CLOSED = when the door is closed again
■
LEAF DELAY
See § 10.3.
■
IN OUT STATUS
The display indicates the status (on / off ), in real time,
of inputs I1-I4, S1-S2 and outputs O1-O2 (§ 9.2).
■
DOOR STATUS
The display indicates, in real time, the status of the
automation (§ 9.3).
■
OTHER BOARD DATA
The display indicates, in real time, useful diagnostics
information (§ 9.6).
■
INTERCOM
See § 10.
■
BOARD DISPLAY
Activating this function inhibits on board program-
ming: the +, - and F buttons are disabled.
It remains locked, even if the KP EVO is disconnected,
until this function is disabled.
■
KPEVO KEY
You can choose between:
-
BLOCK = the user must enter the user password
in order to access the menus that he is authorised
to use.
-
WITHOUT USER PSW = the user must enter the user
password in order to access the menus that he is
authorised to use.
■
CONSECUTIVE OBST.
Specifies the maximum number of consecutive ob-
stacle detections in the same direction of movement,
before stopping in an error condition.
■
TEST ERROR
Specifies the effect that the TEST will have when it
detects a safety device fault.
If this parameter is disabled, the door will remain open
in an error condition.
If it is enabled, the door will continue to operate at
minimum speed.
ERRORS
In this menu, the display indicates any current errors
that there may be in real time (§ 9.5).
WARNINGS
In this menu, the display indicates any current alerts
that there may be in real time (§ 9.4).