A951
52
532081 - RevA
Tr
ansla
tion of the original instruc
tions
ENGLISH
20
TEST failed on an input (I1-I4)
- Check the connections of the safety device
- Check that the safety device is working
-
Replace the Logic board
22
Programming data corrupted
- Reprogram the board or upload the program files that were saved to the USB
storage device
- Replace the Logic board
24
Consecutive obstacles in closing
- Remove the obstacle in closing
- Make sure that the leaf has been mounted correctly and that it moves smoothly,
remove any friction
25
BUS 2easy data not valid
- Check the connections
BUS 2easy
devices
26
Lock failure
- Check the wiring of the lock
- Check that the maximum load of the lock has not been exceeded
- Replace the lock
- Replace the Logic board
27
Motor rotation fault
- Check the polarity of the motor cable
29
Auxiliary board failure
- Check the connection of the auxiliary board
- Replace the display
- Replace the Logic board
31
Consecutive obstacles in opening
- Remove the obstacle in opening
- Make sure that the leaf has been mounted correctly and that it moves smoothly,
remove any friction
34
BUS 2easy devices registration in progress
- Wait for the procedure to be completed
35
BUS 2easy configuration error
- Check the addressing of the
BUS 2easy
devices
- Check that
BUS 2easy
devices are operating correctly
36
BUS 2easy short circuited
- Check the addressing of the
BUS 2easy
devices
- Replace the Logic board
37
BUS 2easy devices error
- Check the addressing of the
BUS 2easy
devices
- Check the addressing of the
BUS 2easy
devices
39
Set-up data missing or corrupted
- Perform setup
-
Replace the Logic board
93
BUS 2easy configuration data corrupted
- Register the
BUS 2easy devices
-
Replace the Logic board
9.6 OTHER BOARD DATA
Go to menu 2.5.11 of the KP EVO, the display provides
information on the following parameters:
-
V MAIN : input voltage to the Logic board (Volts)
-
V ACC : output voltage for accessories (Volts)
-
POS : position of the rotating shaft (degrees)
-
I MOT : current drawn by motor (Amperes)
9.7 FIRMWARE VERSIONS
ON THE BOARD
When the display of the A951 is switched on, it shows
the version of the Logic board firmware for one second
before displaying the status of the automation.
ON THE KP EVO
Go to menu 9 of the KP EVO, or to view the firmware
versions of the bootloader, the Logic board and the
KP EVO.
9.8 LOG DATA
The A951 records the last 512 system events. A
battery must be installed on the Logic board in order
to save the list of events in memory even if the system
is switched off.
To download the data as a text file, see § 13.2.
Summary of Contents for A951
Page 1: ...A951 EN16005...
Page 65: ......