B614 53
732998 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
11. DIAGNOSTICS
11.1 LEDS CHECK
LED
STATUS
IDLE
DL1
BUS
active
not active
DL2
BUS MON
See BUS 2easy device
registration
DL3
RADIO1
active
not active
DL4
RADIO2
active
not active
DL5
Error/alarm “ERROR”
active
not active
DL8
EMER
not active
active
DL9
STOP
not active
active
DL10
CLOSE
active
not active
DL11
OPEN
DL12
LOOP1
active
not active
DL13
LOOP2
active
not active
L
i
In Master-Slave configuration see § 10.
11.2 DIRECTION OF MOVEMENT CHECK
1. Select parameter
M 1
in the Basic program-
ming. The display shows
--.
2. Keep the
+
button pressed. The display shows
oP
and the barrier opens.
3. Keep the
-
button pressed. The display shows
cL
and the barrier closes.
4. If the conditions in points 2 and 3 are not re-
spected, invert the motor wires.
11.3 ENCODER OPERATION CHECK
1. Select parameter
M1
in Basic Programming, the
display shows
--.
2. Keep the
+
button pressed. The display shows
oP
and the barrier opens. The flashing point
between the two letters indicates that the encoder
is operating correctly.
3. Keep the
-
button pressed. The display shows
cL
and the barrier closes. The flashing point
between the two letters indicates that the encoder
is operating correctly.
11.4 AUTOMATION SYSTEM STATUS
CHECK
The E614 display if not in the programming, shows a
code indicating the status the automation is in:
00
Closed
01
Open
02
Stationary then opens
03
Stationary then closes
04
In pause mode
05
Opening
06
Closing
07
Failsafe in progress
08
BUS 2easy device verification in progress
09
Pre-flashing and then opens
10
Pre-flashing and then closes
11
Opening in Emergency
11.5 CHECK FIRMWARE VERSION
When the display of the E614 is switched on, it shows
the following in succession:
-
firmware version (2 digits separated by a point)
-
automation system status
11.6 CHECK OF THE REGISTERED
BUS 2EASY DEVICES
1. Select parameter
bu
in Basic programming.
2. Press and hold the
+
button; the segments relative
to the registered devices will light up (see