3
B614
11
732998 - Rev.A_DRAFT
1
2
Tr
ansla
tion of the original instruc
tions
ENGLISH
B614 220-240 V ~
B614 115 V ~
Supply voltage
220-240 V~ 50/60 Hz
115V~ +/-10% 50/60 Hz
Electric motor
24 V
"
24 V
"
Max power
165 W
165 W
Max torque
300 Nm - 63 Nm (Breakaway - 45°)
300 Nm - 63 Nm (Breakaway - 45°)
Opening time (80°)
- beam 3 m
- beam 5 m
< 2 sec.
< 3 sec.
< 2 sec.
< 3 sec.
Use frequency
100 %
100 %
Ambient operating temperature
-20 °C ... +55 °C
-20 °C ... +55 °C
Ingress protection
IP 55
IP 55
Dimensions (L x D x H)
247 x 357 x 1163 mm
247 x 357 x 1163 mm
Weight
40 kg
40 kg
Base plate FAAC
Dimensions (L x H)
230 x 305 mm
Beam FAAC
Beam length
Rectangular beam
2.00 ... 4.85 m max
Round beam
2.00 ... 5.20 m max
6
Technical data
3.7 MANUAL OPERATION
!
- Performing the release manoeuvre when there is no
electrical power.
- Performing the release manoeuvre only when the beam
is at a standstill.
- During manual handling, accompany the beam slowly
for the entire stroke. Do not let the beam travel freely.
- Do not leave the barrier unblocked: after carrying out
the manual movement, restore automatic operation.
RELEASE PROCEDURE
1.
3
Open the lock cover. Insert the key and turn
it once anticlockwise until it stops (
1
).
2. Move the automation manually.
3. Restore the operation
OPERATION RESTORATION
1.
3
Insert the key and turn it twice clockwise
until it stops (
2
).
2. Check that manual movement is inhibited.
3. Remove the key and close the cover