8.
START-UP
RISKS
PERSONAL PROTECTIVE EQUIPMENT
!
During operation there is a risk of cutting, crushing or the
total loss of hands due to the moving parts inside the box.
If two barriers are installed in the following configura-
tion Master-Slave, before beginning the start up of the
Master, it is necessary to have configured the Slave
barrier (see § 11).
1. Check that the B614 is locked.
2. Power up the plant (
Master
barrier) . The board
lights up and the display then comes on:
-
firmware version (2 digits separated by a dot)
-
SO
flashing if a set-up or the automation status is
requested
3. Check the status of the LEDs at rest (see § 12.1).
The BUS 2easy LEDs must be checked after the devices
have been registered.
4. Memorise the remote controls present on the
plant (see § 10.3).
5. Program E614 without performing the set-up.
!
For the barrier to work properly, set the parameter
cF
dependent on the beam length.
6. Register the BUS 2easy devices, if they are installed
(see § 10.4).
7. Check the barrier's direction of travel (see § 12.2).
8. Perform the set-up (see § 8.3).
9. If the XBAT 24 battery is being used:
-
Cut off the plant's power supply
-
Connect the battery XBAT 24
-
Switch on power to the system.
8.1 PROGRAMMING
BASIC PROGRAMMING
1. Press and hold down
F
until the first basic
function appears. (Each function is displayed
as long as
F
remains pressed).
F
2. Release: the value of the function appears
(default or programmed).
F
3. Use the
+
or
-
button to modify the value.
-
+
4. Press
F
to confirm the value displayed. Go
to the next function. The modified value
becomes effective immediately.
F
Proceed in the same way for all the functions. The last function
(
St
) allows you to close the program.
5. In
St
select
Y
or
no
using the
+
+
/
-
buttons:
Y
= save the new program
no
= DO NOT save the new program
6. Press
F
to confirm and close the program. It returns to the
automation system status view.
To
exit from the programming mode at
any time
:
pressand hold down
F
and then also
-
to move
directly to
St
.
F
+
-