14
8 mm
30-50 mm
~ 1 m
ENGLISH
6.1.3 Calibration
Each time the E680 board is powered, the integrated loop detector
performs a calibration of the connected loops. Therefore, you can
perform calibration by cutting off power to the board for at least 10
seconds and then reconnecting it.
From the barrier status display, you can press, at any time,
+
to
calibrate the loop connected to the LOOP 1 input or
+
to calibrate
the loop connected to the LOOP2 input.
Calibration is highlighted by the board diagnostics by flashing LEDs
DL3 and DL4, and when calibration is completed, they will indicate
the loop detection status, if connected.
The other signals provided by the board diagnostics are described
in the following table:
D
L3
D
L4
LOOP 1
LOOP 2
2 2
2 2
4 5 6 7
If one or both magnetic loops are not installed, the loop
detector, following a first attempt to calibrate, will keep
the status LEDs flashing every 5 seconds (as shown in
the above table)
LED Status
LOOP Status
Off
Loop clear
On
Loop engaged
Flashing (0.5 s)
Loop calibration
in progress
Rapid flashing
Loop short circuit
Slow flashing
(5 s)
No loop
or loop interrupted
Two flashes (every 5 s) Non-conforming loop
(heater or inductance
out of range)
6.1.4 Adjusting sensitivity
By adjusting the sensitivity of the loop detector, you determine the
variation of inductivity, for each channel, that a vehicle must cause in
order to activate the corresponding detector output.
Sensitivity is adjusted separately for each channel using the two
parameters
S1
and
S2
in Basic configuration
6.1.5 Making the loops
The loop must be laid at least 15 cm from fixed metal objects, at least
50 cm from moving metal objects and no more than 5 cm from the
surface of the final paving.
Use a standard unipolar cable measuring 1.5 mm² in diameter (if
the cable is laid below ground level directly, it must have double
insulation). Make a preferably square or rectangular loop by preparing
a PVC cable duct or by tracing the paving, as shown in figure 16 (the
corners must be cut at a 45° angle to avoid cable breaks). Lay the
cable using the number of windings shown in the table. The two ends
of the cable must be twisted together (at least 20 times per metre)
from the loop to the E680 board. Avoid splicing a cable (if necessary,
weld the conductors and seal the splice using a heat-shrinking sheath)
and keep it separate from the mains power lines.
Loop
Perimeter
Nr.
of Windings
less than 3 m
6
from 3 to 4 m
5
from 4 to 6 m
4
from 6 to 12 m
3
more than 12 m
2
6.2
Expert Configuration
EXPERT configuration is used only in the event that operation logics customisation is already stored.
Before making changes at this level, be certain that the steps you wish to change and their effect on the automated
system are fully understood.
Changing the third-level parameters involves indicating the
CU
value on the
LO
parameter of the first-level programming
To access EXPERT configuration,
press F and, holding it, press + for approximately 10 seconds
.
The use of
F
,
+
and
-
in this menu is the same as in the other two programming levels
“EXPERT” CONFIGURATION 10 sec
Display
.
Function
Setting
0 1
If this function is activated,
automatic closing
occurs after the pause time.
Y
= automatic closing
no
= disabled
02
If this function is activated,
two distinct input
operation mode is obtained: OPEN for
opening and CLOSED for closing.
Y
= 2-input operation
no
= disabled
03
Activation of recognition of the
OPEN and CLOSE input levels (maintained command)
.
That is to say, the board recognises the level (if, for example, with OPEN held, you press
STOP, when the latter is released, the automated system will continue to open). If
03
is
disabled
the board commands a manoeuvre only if there is an input variation.
Y
= level recognition
no
= status variation
recognition
Summary of Contents for B680H
Page 1: ...B680H ...
Page 2: ......
Page 4: ......
Page 151: ...27 a b c d e f g h Fig 17 L ...
Page 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Page 153: ...29 a b Fig 21 d e f c ...
Page 156: ...32 Fig 31 a b c d e ...
Page 157: ...33 Fig 32 f g ...
Page 158: ......
Page 163: ...5 1 2 Fig 18 ...
Page 164: ......
Page 165: ......