22
ENGLISH
In brackets, the effects on the other inputs when the pulse is active
LOGIC “CA”
PULSES
AUTOMATED
SYSTEM STATUS
OPEN A
CLOSE
STOP
FSW
LOOP 1
LOOP 2
CLOSED
opens and closes
after the pause
time
no effect
no effect
(opening inhibited)
no effect
opens and closes
after the pause
time
no effect
WHEN OPENING
no effect
closes
immediately
after opening is
completed
blocks
operation
no effect
no effect
closes
immediately
after opening is
completed
OPEN IN PAUSE
resets pause time
closes
blocks
operation
resets pause
time
(closing inhibited)
resets pause time
closes when
disengaged
WHEN CLOSING
immediately
reverses to
opening
no effect
blocks
operation
reverses to
opening and clo
-
ses after pause
time
immediately
reverses to
opening
immediately
reverses to
opening
BLOCKED
opens and closes
after the pause
time
closes
no effect
(opening and
closing inhibited)
no effect
(closing inhibited)
opens and closes
after the pause
time
no effect
(closing inhibited)
LOGIC “C”
MAINTAINED COMMANDS
PULSES
AUTOMATED
SYSTEM STATUS
OPEN A
CLOSE
STOP
FSW
LOOP 1
LOOP 2
CLOSED
opens
no effect
no effect
(opening inhibited)
no effect
no effect
no effect
WHEN OPENING
/
no effect
blocks
operation
no effect
no effect
no effect
OPEN
no effect
(closing inhibited)
closes
blocks
operation
no effect
no effect
(closing inhibited)
no effect
(closing inhibited)
WHEN CLOSING
immediately
reverses to
opening
/
blocks
operation
blocks
operation
blocks
operation
blocks
operation
BLOCKED
opens
closes
no effect
(opening and
closing inhibited)
no effect
(closing inhibited)
no effect
(closing inhibited)
no effect
(closing inhibited)
Tab. 1/g
Tab. 1/h
Summary of Contents for B680H
Page 1: ...B680H ...
Page 2: ......
Page 4: ......
Page 151: ...27 a b c d e f g h Fig 17 L ...
Page 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Page 153: ...29 a b Fig 21 d e f c ...
Page 156: ...32 Fig 31 a b c d e ...
Page 157: ...33 Fig 32 f g ...
Page 158: ......
Page 163: ...5 1 2 Fig 18 ...
Page 164: ......
Page 165: ......