C4000I
39
532100 - Rev.A
Tr
ansla
tion of the original instruc
tions
ENGLISH
with an obstacle and check the LEDs on the pho-
tocells, the status of the bus on the display and the
automation system operate according to the type
of photocell installed.
WIRELESS SAFETY EDGE SYSTEM
Type of use:
Closing safety
edges (SAFE
CL)
Ac tive during
closing
When an obstacle is detected,
they stop the gate and reverse
the direction of movement.
Opening safe-
ty edges (SAFE
OP)
Ac tive during
opening
When an obstacle is detected,
they stop the gate and reverse
the direction of movement.
Select the type of reverse, complete or partial (func-
tion
IP
Advanced programming).
The BUS 2easy provides power to and enables com-
munication between the wireless safety edge system
receiver and the electronic board.
The BUS line does not require a matching polarity
connection.
1. Memorise the wireless safety edge system trans-
mitters (see the device instructions).
2. Register the radio system (function
b u
Basic
programming).
Do not assign BUS 2easy addresses used by the
wireless safety edge system to other devices (e.g.
photocells):
- 0110 (OFF ON ON OFF)
Opening safety device
- 1101 (ON ON OFF ON)
Closing safety device
If the addresses have already been assigned, the board
will have a conflict error.
3. Check the status of LEDs DL3 and DL7 (
)
4. Make sure that the wireless safety edge system is
operating correctly. When the gate is moving, acti-
vate the safety edge and check that the LEDs on the
radio system transmitter and receiver, the status of
the bus on the display and the automated system
operate according to the type of edge installed.
CONTROL DEVICES
1. Position the DIP switches to assign the commands.
Stop NC also generates a stop when the device is
disconnected. A command (e.g.: OPEN A_1) must
be used on only one of the connected devices.
11
Addressing control devices
0 0 0 0
Open A_1
0 0 0 1
Open A_2
0 0 1 0
Open A_3
0 0 1 1
Open A_4
0 1 0 0
Open A_5
0 1 0 1
Stop
0 1 1 0
Stop NC_1
0 1 1 1
Stop NC_2
1 0 0 0
Close
1 0 0 1
Open B_1
1 0 1 0
Open B_2
1 0 1 1
Open B_3
1 1 0 0
Open B_4
1 1 0 1
Open B_5
1 1 1 0
/
1 1 1 1
/
0 0 0 0
Open A_1
Open B_1
0 0 0 1
Open A_1
Open B_2
0 0 1 0
Open A_1
Stop
0 0 1 1
Open A_1
Close
0 1 0 0
Open A_2
Open B_1
0 1 0 1
Open A_2
Open B_2
0 1 1 0
Open A_2
Stop
0 1 1 1
Open A_2
Close
1 0 0 0
Open A_3
Open B_3
1 0 0 1
Open A_3
Open B_4
1 0 1 0
Open A_3
StopNC_1
1 0 1 1
Open A_3
Close
1 1 0 0
Open A_4
Open B_3
1 1 0 1
Open A_4
Open B_4
1 1 1 0
Open A_4
StopNC_2
1 1 1 1
Open A_4
Close
2. Register the BUS 2easy control devices (
bu
Basic
programming).
3. Check the status of LEDs DL3 and DL7 (
).
4. Check that the devices are working properly. Use
the controls to make the gate move. Check the
LEDs on the devices, the status of the bus on the
display and make sure that the automation system
operates according to the type of device installed.
BUS 2EASY DEVICE REGISTRATION
Registration is required:
-
When the automation system is first started or after
the board has been replaced.
-
Following any changes (addition, replacement or
ON
1 2 3 4 5
1 command
DIP switch 5 =
0 (OFF)
ON
1 2 3 4 5
2 commands
DIP switch 5 =
1 (ON)