9
ENGLISH
ENGLISH
2. PROGRAMMING
To program operation of the automated system, you have to
access the “PROGRAMMING” mode.
Programming is split into two parts: BASIC and ADVANCED.
2.1 HOW TO ACCESS PROGRAMMING
To access
BASIC PROGRAMMING, when on stand-by, press key
F
(the first basic function is shown).
To access
ADVANCED PROGRAMMING, when on stand-by or from
inside basic programming, press key
F
and, while you hold it down,
press key
+
(the first advanced function is shown).
If you release key
F
(basic programming) or
F
and
+
(advanced
programming), the value of the current function is shown, and
can be modified with push-button
+
or
-
.
Next:
• if you press
F
(and hold it down), the display shows the name of
the next function;
• if you release key
F
, the display shows the value of the function
which can be modified with keys
+
and
-,
etc….;
• at the end, Digiprogram returns to stand-by mode.
The following tables indicate the sequence of functions accessible
with BASIC PROGRAMMING and ADVANCED PROGRAMMING.
+
+
F
TIME LEARNING (see chapters 4 and 5)
Enables the selection between “simple” (automatic)
learning and “complete” (manual choice of
deceleration and stop points) learning.
Note: wait for the
to light up steady after a few
seconds of flashing, before starting the learning cycle.
Simple learning
1 sec.
Complete learning
> 3 sec.
Exit without time learning
LEAF 1 CLOSING DELAY
Delays closing start of leaf 1 with respect to leaf 2.
Programmable
from
to
minutes (for the
adjustment mode, see Pause time).
LEAF 2 FORCE
Adjusts thrust of Motor 2.
Programmable
from
(minimum force)
to
(maximum force)
LEAF 1 FORCE
Adjusts thrust of Motor 1.
Programmable
from
(minimum force)
to
(maximum force)
PAUSE TIME
This has effect only if an automatic logic was selected.
Adjustable from to
sec. in one-second steps;
subsequently, display changes to minutes and tens of
seconds (separated by a dot) and time is adjusted in 10-
second steps, up to the maximum value of
minutes.
E.g. if the display shows
, pause time is 2 min. and 50
sec.
FUNCTION LOGICS
= Automatic
= Semi-automatic
= “Safety” Automatic
= “B” Semi-automatic
= Dead-man
= “Stepped” Automatic
=“Stepped” Semi-automatic
=”Stepped” Safety Automatic
BASIC PROGRAMMING
Digiprogam is an external programmer used for configuring the
462F control board.
1. DIGIPROGRAM CONNECTION
Using the supplied cable, connect Digiprogram to board 462DF
as shown in fig. 1. Digiprogram has no internal battery of its own
because it is powered directly by the control board.
As soon as it is connected, the Digiprogram display shows
for
two seconds to let you check if all segments and dots are correctly
powered up. After this, the Digiprogram goes into stand-by,
displaying the status of inputs (see Chapter 3).
ATTENTION: the safety devices are disabled
during the learning procedure! Therefore,
carry out this operation avoiding any transit
through the leaf movement area.
F
Display
Function
Default
fig.1