A
A
CCESSORY
CCESSORY
C
C
ONNECTIONS
ONNECTIONS
A
CCESS
C
ONTROL
C
ONNECTION
:
Access Control Devices such as Telephone Entry Systems, Digital Locks and Card Readers may be connected to the Access
Input to control the gate operator. When an Access Device is active, the Access LED will light.
F
IRE
L
OCK
C
ONNECTION
:
Fire Lock Controls such as Knox Locks and Fire Boxes may be connected to the Fire Input to control the gate operator. When
a Fire Lock Control is active, the Fire LED will light.
Fire Input:
1. Allows Fire Lock Controls to activate the gate.
2. This input knows the position of the gate and will only open the
gate when activated.
3. If Close Time Delay is ON, gate will open and remain open until
the fire control relay is released. Then the gate will time out and
close.
4. If Close Time Delay is OFF and the gate is in closed position,
gate will open and remain open until an external input of any
sort closes the gate.
5. If Close Time Delay is OFF and gate is in open position, gate
will remain open until an external input is made. This prevents
the Fire Input from closing the gate if in the open position.
Connecting Access Devices:
1. Connect Fire Lock Control relays to FIRE and COMMON.
(Most devices use Normally Closed & Common)
NOTE: Consult your local Fire Department for proper
building codes and Fire Lock requirements.
FIRE
LOCK
Access Input:
1. Allows external Access Control Devices to activate the gate.
2. If Close Time Delay is ON, gate will open and remain open until
the access device relay is released. Then the gate will time out
and close.
3. If Close Time Delay is OFF and the gate is in closed or open
position, gate will travel in the opposite direction.
4. If Close Time Delay is OFF and the gate is in mid cycle, the
gate will stop. The direction will not be changed until another
valid input is made.
Connecting Access Devices:
1. Connect Access Control Device relays to ACCESS and
COMMON. (Most devices use Normally Open & Common)
1 2
3
4 5
6
7 8
9
*
0
#
Card Access
1
2
3
4
5
6
7
8
9
*
0
#
Phone Entry
DO NOT allow children to play near, on or with
the gate, gate operator, or any of its controls.
!
DSW2000 Swing Gate Operator