Control Board LED Lights
- The control board LED lights are located above their respec-
tive terminals that they represent. (With exception of ALIM, power supply light, which is located
below the power terminals in the upper left corner.) The LED lights are a quick way of verifying
necessary connections are made. Below is a chart of their interpretations.
LED Lights & Operational Displays
LED
ON
OFF
ALIM
Powers supply by transformer
Power supply by battery or no power
FCC 1
Motor 1 closing limit switch - not tripped
Motor 1 closing limit switch - tripped
FCA 1
Motor 1 opening limit switch - not tripped Motor 1 opening limit switch - tripped
FCC 2
Motor 2 closing limit switch - not tripped
Motor 2 closing limit switch - tripped
FCA2
Motor 2 opening limit switch - not tripped Motor 2 opening limit switch - tripped
STOP
Stop command - not activated
Stop command - activated
FSW CL Closing safety device - not tripped
Closing safety device - tripped
FSW OP Opening safety device - not tripped
Opening safety device - tripped
During idle for single gate openers, all should be on except FCC 2 and FCA 2. During idle
for dual gate openers, all LED lights should be on.
If not using safety devices , you must jump STOP, FSW CL and FSW OP to COM in order
for the gate opener to function.
Standard Operation Display
-
This is when the gate opener is not in parameter setting
mode or programming mode. LED displays DS1 and DS2 will show the following:
Gate Status
Gate At Rest in Closed Position
Gate Opening or Gate Open when Auto Close is OFF
Gate open in pause status
(Only with automatic re-close enabled - Parameter c)
Gate Closing
6.1