Standard System
Overview and Safety Zones
The system display to the below is a recom-
mended standard system. Other approved
accessories can be installed. Photo sensors
and a flashing light indicating gate move-
ment is recommended for safety purposes.
IMPORTANT
Preliminary Checks:
To ensure safety and an efficiently operating automated system, make sure the follow-
ing conditions are observed.
The gate and post must be suitable for being automated. Check that the structure is
sufficiently strong and rigid, and its dimensions and weights conform to those
indicated on page 1.
Make sure the leaves move smoothly without any irregular friction during entire
travel.
Make sure the hinges are in good condition. Ball bearing hinges are ideal for gates
weighing over 200 lbs. or over 10’ in length.
Make sure the gate is plumb and level.
The fence post must be secured in the ground with concrete. This will prevent
alteration of alignments and leveling during installation and during cycles.
1.3
1,2
Estate Swing Operator
3
Photocells (not included)
4
Master control board
5
Slave control board
6
Push button opening device (not included)
7
Receiver extension (not included)
8
12Vdc flashing lamp (not included)
9
Positive stop
10
AC transformer
Notes:
1) When laying electrical cables, use appropriate rigid and/or
flexible tube.
2) Do not run any wires in the same conduit as 110 AC pow-
er that may be in the area. This will cause unwanted interfer-
ence.