E145
4
732783 - Rev.C
ENGLISH
Translation of the original instructions
3.1 BASIC PROGRAMMING
Display
Basic Function
Default
CF
MOTOR TYPE
:
1
Motors for swing gates
2
Motors for sliding gates
PC
Mixed configuration from a PC/MAC (e.g.: one swing and one slide)
dF
DEFAULT:
Y
Indicates that all the set values are default values.
no
Indicates that at last 1 set value is different from the default values.
Select
Y
if you wish to restore the default configuration.
Y
LO
OPERATING LOGIC:
E
,
EP
,
S
,
SA
,
SP
,
A1
,
A
,
AP
,
At
,
b
,
bC
,
C
,
CU
Refer to the specific paragraph for a description of the operating logics.
E
PA
PAUSE A TIME (only displayed with Automatic logic):
Can be adjusted from
00
to
9.5
minutes.
30
Pb
PAUSE B TIME (only displayed with Automatic logic):
Can be adjusted from
00
to
9.5
minutes.
30
Mn
NUMBER OF MOTORS:
1
= 1 motor
2
= 2 motors
2
(
swing
)
1
(
sliding
)
F1
MOTOR 1 POWER:
01
= minimum power
50
= maximum power
25
F2
MOTOR 2 POWER (only displayed with the
Mn
=
2
function):
01
= minimum power
50
= maximum power
25
En
ENCODER USE:
Y
= encoders on both motors
no
= disabled encoders
no
FA
LIMIT SWITCH WHEN OPENING
(only displayed with the
CF
=
1
or
CF
=
PC
function):
no
= opening limit switches disabled
01
= the limit switch determines when the movement is stopped
02
= the limit switch determines when deceleration begins
no
FC
LIMIT SWITCH WHEN CLOSING
(only displayed with the
CF
=
1
or
CF
=
PC
function):
no
= closing limit switches disabled
01
= the limit switch determines when the movement is stopped
02
= the limit switch determines when deceleration begins
no