E145
9
732783 - Rev.C
ENGLISH
Translation of the original instructions
Operation WITHOUT Encoder
Stop the movement by sending an OPEN
A pulse as soon as leaf 1 reaches the
mechanical stop.
Operation WITH Encoder
Leaf 1 will stop as soon as it reaches the me-
chanical stop. If there is no mechanical stop,
stop the leaf movement at the desired point by
sending an OPEN A pulse.
8.
The board will automatically exit the programming menu and will display the status of the automated
system (
00
) as confirmation that the SET-UP procedure has been completed correctly. If the
procedure is not completed correctly,
S0
will start flashing on the display, indicating that a new
SET-UP procedure must be performed.
The deceleration spaces can be configured and modified from the
r1
and
r2
parameters on the display (refer to Advanced Programming) without having to
repeat the SET-UP.
Refer to the complete instructions if there are limit switches.
5.
USEFUL PARAMETERS TO PROTECT AGAINST THE RISK OF IMPACT/
CRUSHING ON THE MAIN EDGE
PARAMETER
FUNCTION
F1
Allows the static thrust force of motor 1 to be adjusted.
NOTE: For hydraulic operators, set the force value to maximum and adjust it via
the bypass screws.
F2
Allows the static thrust force of motor 2 to be adjusted.
NOTE: For hydraulic operators, set the force value to maximum and adjust it via
the bypass screws.
En
Enables the encoders to be read by the electronic board, thereby guaranteeing
that inversion occurs in the presence of obstacles (set
EN
=
Y
).
Cd
Allows the closing delay of motor 1 to be modified in order to obtain a phase shift
between the two leaves and reducing the risk of crushing between the two moving
leaves.
r1
Allows the space of reduced speed of leaf 1 to be adapted. The impact at slow
speed allows the dynamic force to be reduced.
r2
Allows the space of reduced speed of leaf 2 to be adapted. The impact at slow
speed allows the dynamic force to be reduced.
EC
Allows the obstacle inversion sensitivity to be adjusted.
rB
Allows the space before the mechanical stops in which the board does not per-
form inversions to be modified (set a value between 1 and 49 mm).
6. OPERATING LOGIC
This table summarises the operating logic.
Refer to the complete instructions for a detailed description of each.
LOGIC
Status of the automated
system:
stopped
Status of the automated
system:
in motion
Status:
photocell action
E
Semi-automatic An OPEN pulse opens the
gate and the following one
closes it
An OPEN pulse stops the
gate when opening and
reopens when the gate is
closing
The photocells invert during motion