7.2
After programming your last parameter you may now move on to
programming your gate movement. Press P2 one more time to exit
this mode. Gate movement instructions begin on the next page.
Operating Parameters Chart
A1, A2, A3, A4
Force: 1 = Obstructs easily, 4 = Obstructs less sensitive
Obstruction is when gate meets resistance motor stops and reverses directions
C0, C1
0 = Auto reclose off, 1 = Auto reclose on
Time delay set during run time learning process
D0, D1
0 = open/close/open, 1 = open/stop/close/stop
Sequencing when remote or OPEN A is triggered
E0, E1
0 = Condo function off, 1 = Condo function on
Condo function ignores signal from OPEN A or remote during an open cycle
G0, G1
0 = Flashing lamp, 1 = Steady on lamp (2 minute)
For 24V lamp terminal output
H1, H2, H3, H4
1 = 10%, 2 = 20%, 3 = 30%, 4 = 40%
Percentage of run time in slow down
I0, I1
0 = Slow down speed quarter speed, 1= slow down speed half speed
L0, L1
0 = encoder only, 1 = limits and encoder
Encoder is a device that records number of motor turns from closed to open
Recommended to use 1 setting
N0, N1
0 = pre-flashing off, 1 = pre-flashing on
For 24V lamp terminal, pre-flashing is a delay that allows lamp to flash
before closing as a warning of closing about to occur
O0, O1
0 = photocell close off, 1 = photocell close on
When open and in auto-reclose count down, photo cell wired in closing safety
if triggered and released makes gate close immediately
P0, P1
0 = auto-reclose override off, 1 = auto-reclose override on
Auto-close override is a trigger from OPEN A or remote causes auto-reclose
to be skipped and gate to close immediately
R0, R1
0 = Final brake off, 1 = Final brake on
If on there is a slight braking to decrease remaining momentum
before stopping