10
ENGLISH
ENGLISH
Before carrying out the masonry works required to make the
lane, prepare all the channels/ducts/raceways essential for
cable routing, for electrical connection of the system’s equip-
ment.
Lay the cable ducts, scrupulously observing the indications
shown in the lay-out below.
Separate ducts must be provided between: high voltage (230
Vac power cables) and low voltage (cables for: commands,
safety, intercom, serial data line, etc.).
Furthermore, appropriately size the diameter of the cable ducts
to be laid, in relation to the cross-section and number of cables
to be inserted. To this end please refer to section
3. Electrical
preparations
of this manual.
Channel lay-out for Exit lane
Driving direction
1 Input of Ticket Reader power cables
2 Input and output of cables for data transmission line on RS 485
protocol
3 Input for intercom line cables
4 Vehicle Presence loop
5 Vehicle Transit loop
6 Open/Closed barrier co transit loop safety contact
7 Input of barrier power cables
2.6 PREPARATION OF CHANNELS
Fig. 8