7
a
b
c
ENGLISH
4 MANUAL OPERATION
OPEN
CLOSED
UNLOCKED
LOCKED
Fig. 18
5 ELECTRICAL CONNECTION OF THE "2easy bus" ENCODER
The S450H operator is fitted with an encoder system with "2easy bus" technology. The proper assignment of the leaf to the corresponding
encoder depends on the connection of the two encoder wires (leaf 1- encoder 1; leaf 2 - encoder 2).
THE ENCODER WIRES MUST BE CONNECTED TO THE "2easy bus" CONNECTOR OF THE ELECTRONIC EQUIPMENT.
To verify the proper combination
LEAF - ENCODER - MOTOR
and
LEAF 2 - ENCODER 2 - MOTOR 2
, refer to the LEDs on the
encoders, as shown by table 2 and the figures 19 - 20 - 21.
To invert the leaf-encoder combination, change the encoder polarity by swapping its wires until the right LEDs are lit.
TABLE 2
LED
ON
BLINKING
OFF
DL
Power supply ON and BUS - board
communication
Power supply ON but
no BUS communication
(e.g.: cabling fault)
Power supply OFF and no BUS communi-
cation
(e.g.: missing or broken connection)
DL 2
Encoder associated to leaf
/
Encoder associated to leaf 2
DL
/
Pulse reading during leaf movement
Leaf stationary
DL
:
must always be ON
to ensure the right connection between encoder and board.
DL 2: indicates the leaf where the encoder is installed.
If the encoder is installed on leaf 1, the DL 2 LED is ON.
If the encoder is installed on leaf 2, the DL 2 LED is OFF.
DL :
when
blinking
at regular intervals, it signals the pulse reading
during the leaf
movement
.
When the gate leaf is stationary, DL is OFF.
If the gate is to be operated manually because of a power failure or an automated system fault, activate the release device.
1) Lift the protection lid (Fig. 18, re.
a
) and insert the key in the lock (Fig. 18, ref.
b
).
2) Turn the key 90° clockwise to open the cover and lift it.
) Turn the release knob (Fig. 8, re.
c
) anticlockwise until it stops.
4) Open or close the leaf manually.
To restore the normal operation of the automated system, perform the above described operations in reverse order.
The LEDs of the encoder remain visible also with the protection cover of the rear
bracket installed.
The models S450H SB are not equipped with a release facility since, thanks to the particular configuration of the hydraulic
distributing flange, you do not need to release the operator to manually move the leaf
www.metalines.com