A
B
C
Fig.7
Fig.9
Fig.10
Fig.11
10) Place the supplied plastic wrench with the spacer under the
operator, as shown in figure 10 ref. B, C
12) Insert and tighten the fastening long bolts with the supplied
lockwasher as shown in Fig. 10 ref. C, in order to secure the
operator to the load bearing box as shown in Fig. 11.
13) Close the gate and check if the closing travel-limit stop is
correctly positioned; if necessary, adjust the travel-limit stop,
referring to the instructions in paragraph 3.2.
14) Open the gate and check if the opening travel-limit stop
is correctly positioned; if necessary, adjust the travel-limit stop,
referring to the instructions in paragraph 3.2.
15) Hydraulically re-lock the operator
7) Turn the operator pinion with the supplied wrench until it points
to the open position (90° from close) and then remove the wrench
(see Fig. 7)
Fig.8
8) Grease the pinion and insert the operator in the load bearing
box as shown in Fig.8-9,
9) Raise the operator with its handles (Fig.10 ref. A), inserting the
pinion in the splined collar of the load bearing box. To facilitate
the operation, slightly wiggle the operator until coupling takes
place.
9