OK
L
N
230 V ~
*
230 V ~
L
N
L
A
A
OK
ENGLISH
5
3.3 ELECTRIC CONNECTIONS
1) Cut power supply before attempting any job on the system.
2) Install an omnipolar switch with contact opening distance of 3 mm or greater on the power supply mains of
the automated system.
3) Wire the cables according to the diagram; if the motor rotates in the opposite direction, do not reverse the
black and brown wires, as at the end of the set-up, the up or down push-buttons are automatically matched
to the correct direction of motor rotation.
Fig.6
*
ATTENTION: IF A PUSH-BUTTON
COMMAND IS NOT USED, DO NOT
CONNECT THE BLACK WIRE.
ATTENTION
: the push-button has a step-by-step logic with dead-man control. Every time the push-button is pressed,
an impulse is sent to the motor (EXAMPLE: FIRST PRESSING HELD OF THE PUSH-BUTTON: UP; PUSH-BUTTON RELEASE: STOP;
SECOND PRESSING HELD; DOWN etc.)
3.3.1 MOTOR OPERATED BY REMOTE CONTROL ONLY
3.3.2 MOTOR OPERATED BY REMOTE CONTROL AND PUSH-BUTTON
BROWN
BROWN
BLUE
BROWN
BLUE
YELLOW-GREEN
YELLOW-GREEN
Fig.7
RED OR
BLACK
RED OR
BLACK
RED OR
BLACK