background image

a

b

ENGLISH

7

PROGRAMMING 

PUSH-BUTTON

5.2 SET-UP FOR ROLLING SHUTTERS

The automatic set-up can only be executed if the motor is installed on rolling shutters with an upper mechanical 

stop (e.g.: rising travel limit plugs Fig.10 ref. 

b

 ) and with the mechanical sensor for obstacle detection (Fig.10 ref.  

a

 ) or motor model TM35 ERO

. If this procedure is performed, the motor sets all travel limits automatically.

5.1 FUNCTIONS SET WHEN THE APPLICATION TYPE IS DEFINED IN THE SET-UP MODE

MECHANICAL 

SENSOR 

FOR OBSTACLE 

DETECTION

UPPER 

MECHANICAL 

STOP

Fig.10

   WHEN THE AUTOMATIC SET-UP IS PERFORMED, THE MOTOR SETS IN THE ROLLING SHUTTER MODE.

5.2.1 AUTOMATIC SET-UP FOR ROLLING SHUTTERS ( only for rolling shutters in the configuration described below )

  1) DURING THE MEMORY STORING OF THE FIRST REMOTE CONTROL AND TILL THE END OF THE SET-UP PROCEDURE OF THE TRAVEL 

LIMITS, THE MOTOR OPERATES IN DEAD-MAN MODE. (PUSH-BUTTON HELD DOWN)

 

2) BEFORE COMPLETING THE SET-UP, THE MOTOR COULD ROTATE IN THE OPPOSITE DIRECTION TO THE GIVEN COMMAND (E.G.: YOU 
PRESS THE UP PUSH-BUTTON AND THE ROLLING SHUTTER LOWERS) ; AT THE END OF THE SET-UP, THE UP OR DOWN PUSH-BUTTONS 
ARE AUTOMATICALLY MATCHED TO THE CORRECT DIRECTION OF ROTATION.

 

3) IF THE SET-UP PROCEDURE HAS NOT BEEN PERFORMED OR COMPLETED, WHEN PRESSING A PUSH-BUTTON ON THE REMOTE 
CONTROL, THE MOTOR DOES NOT  MOVE SMOOTHLY, BUT MAKES A SMALL STEP FIRST.

R O L L I N G 
SHUTTERS

STANDARD 

AWNINGS

CASSETTE 

AWNINGS

1) Obstacle detection while lowering.     (OBSTACLE DETECTION)
    (ONLY WITH MECHANICAL SENSOR FOR OBSTACLE DETECTION OR MOTOR TM35 ERO)
2) Detection of ice on the rolling shutter guides or bolts while rising  (ANTI_ICE)
(Modification of the position at the end of detection, torque can be modified during the travel - 100% default)
3) Torque reduction during the last centimetres before the travel limits, with possibility to modify it on 4 levels:   
40% , 60%  ,  80%  , 100 % (default)  of rated torque.    ( SOFT TOUCH )
4) After the automatic set-up, the up travel limit is lower than the mechanical stop point
   ( This avoids useless tensioning of the rolling shutter )
5) Possibility of modifying the obstacle detection sensitivity on 10 levels and the torque in the last centimetres before the 
travel limits
6) During set-up, the first confirmation movement occurs in the opposite direction to the last movement.

1) Detection of possible winding blocks when rising, and following automatic shut-off of the motor.
2) During set-up, the first confirmation movement occurs in the opposite direction to the last movement.
3) Torque reduction during the last centimetres before the travel limits, with possibility to modify it on 4 levels:   
40% , 60%  ,  80%  , 100 % (default)  of rated torque.    ( SOFT TOUCH )

1) Search for the up travel limit at each total winding cycle. (BOX ALWAYS CLOSED)
    ( This function balances in a totally automatic way  the awning cloth extension  )
2) Torque reduction in the last centimetres before the up travel limits , with possibility to modify it on 4 levels:   
40% , 60%  ,  80%  (default) , 100 %   of rated torque.    ( SOFT TOUCH )
    ( It enables a softer closure of the cassette, without stressing mechanical parts and the awning cloth)
3) Cloth release after cassette closure  ( RELEASE SYSTEM )
    ( It enables to eliminate any awning tensioning, without having to reopen the box )
4) Detection of possible winding blocks when rising, and following automatic shut-off of the motor.
5) During set-up, the first confirmation movement occurs in the opposite direction to the last movement.

   After setting the up travel limit, the motor performs N movements in both directions, to confirm the performed memory 

storing of the up travel limit and of the operating mode being set :   

 

 

 

 

 

- 1 confirmation movement in both directions = rolling shutter mode selected and up travel limit set 

 

 

- 2 confirmation movements in both directions = standard awning mode selected and up travel limit set   

 

- 3 confirmation movements in both directions = cassette awning mode selected and up travel limit set

   IF ANTI-INTRUSION DEVICES HAVE BEEN FITTED ON THE TUBE, WE RECOMMEND YOU TO PERFORM AN AUTOMATIC SET-UP PROCEDURE 

AS INDICATED IN CHAPTER 5.2.2 OR A MANUAL SET-UP PROCEDURE

Summary of Contents for T-MODE TM 35 ER

Page 1: ...T MODE TM 35 ER TM35 ERO TM 45 ER TM 58 ER...

Page 2: ...tem is 2 5 m 9 Make sure that a differential switch with trip threshold of 0 03 A is fitted upstream of the system 10 Several motors can be connected with the same inverter if the latter supports the...

Page 3: ...OR DIAMETER mm L LENGTH WITH ADAPTER mm PROTECTION CLASS 8 17 8 20 4 17 230 50 130 0 6 50 45 440 IP44 15 17 15 20 4 17 230 50 180 0 8 50 45 465 IP44 20 17 20 20 4 17 230 50 230 1 50 45 480 IP44 30 17...

Page 4: ...fore fitting the wheel adapter fig 2 ref b A already built in in model TM35 ERO 3 Lock the adapter with the supplied stop Fig 2 ref c 4 Make sure that the adapter is well secured Fig 2 ref c 3 2 INSTA...

Page 5: ...or down push buttons are automatically matched to the correct direction of motor rotation Fig 6 ATTENTION IF A PUSH BUTTON COMMAND IS NOT USED DO NOT CONNECT THE BLACK WIRE ATTENTION the push button...

Page 6: ...UTTONS ARE AUTOMATICALLY MATCHED TO THE CORRECT DIRECTION OF ROTATION Fig 8 Fig 9 WITHIN 10 SECONDS 5 SET UP SETTING THE TRAVEL LIMITS The SET UP procedure enables you to set by pressing the connected...

Page 7: ...travel limit is lower than the mechanical stop point This avoids useless tensioning of the rolling shutter 5 Possibility of modifying the obstacle detection sensitivity on 10 levels and the torque in...

Page 8: ...e automatic semiautomatic or manual set up procedure FIND THE PUSH BUTTON CONTROLLING THE RISE AND HOLD IT DOWN UNTIL THE MOTOR ROTATES IN BOTH DIRECTIONS END OF SET UP BEFORE COMPLETING THE SET UP TH...

Page 9: ...onds Release it and hold it down again until the motor per forms a brief movement in both directions to check the correct setting of both the rolling shutter mode and the travel limit 3 Press the push...

Page 10: ...AND HOLD IT DOWN AGAIN TILL THE END OF THE INDICATED MOVEMENTS TO CONFIRM THE PERFORMED MEMORY STORING OF THE UP TRAVEL LIMIT WITHIN 3 SECONDS 2 seconds 1 second PRESS THE UP OR DOWN PUSH BUTTON AND T...

Page 11: ...2 seconds Release it for 1 second and hold it down until the motor performs a brief movement in both directions to check the correct setting of both the rolling shutter mode and the down travel limit...

Page 12: ...on controlling the lowering and go to the down travel limit 4 Press the stop preferred position push button until the motor performs a brief movement in both directions 5 Check if the travel limit pos...

Page 13: ...THE DOWN TRAVEL LIMIT 1 Press the up or down push button and take the awning to the selected position for the DOWN travel limit Release the push button 2 Press the stop preferred position push button...

Page 14: ...ESS THE UP OR DOWN PUSH BUTTON AND TAKE THE AWINING TO THE UP TRAVEL LIMIT OR DOWN TRAVEL LIMIT UP TRAVEL LIMIT PRESS TWICE THE STOP PREFERRED POSITION PUSH BUTTON FOR 2 SECONDS RELEASE IT FOR 1 SECON...

Page 15: ...rrectly If the travel limits have not been set correctly execute a reset and repeat the set up procedure 5 4 SET UP FOR CASSETTE AWNING BEFORE COMPLETING THE SET UP THE MOTOR COULD ROTATE IN THE OPPOS...

Page 16: ...e push button controlling the rise and go to the up travel limit 4 Press 3 times the stop preferred position push button release it for 1 second and hold it down again until the motor performs a brief...

Page 17: ...ming push button for 7 seconds 3 The motor performs a brief movement in both directions to confirm the performed memory storing 7 seconds RESET OK Every pressing 2 seconds PRESS THE UP OR DOWN PUSH BU...

Page 18: ...EMOTE CONTROLS 1 Supply power to the motor 2 On an already memory stored remote control press the PROGRAMMING push button for 2 seconds and within 5 seconds press the STOP PREFERRED POSITION push butt...

Page 19: ...to the motor after approx 10 seconds the motor operates in both directions for 1 second signalling that the memory has been completely deleted 3 Cut power again to the motor Disconnect the red or blac...

Page 20: ...80 dof total torque default for cassette awning 4 UP PUSH BUTTON PRESSINGS UP HELD DOWN TILL CONFIRMATION 100 of total torque default for rolling shutters and standard or fall type awnings x N times...

Page 21: ...after the rolling shutter has been blocked for 0 2 seconds Down travel limit Up travel limit STANDARD SENSITIVITY AREA Power to the motor is cut after the rolling shutter has been blocked for 1 secon...

Page 22: ...icetheSTOP PREFERREDPOSITIONpush button everypressing 2 seconds and within 1 second press the STOP PREFERRED POSITION push button for 5 seconds to confirm the performed setting WITHIN 1 SECOND The mot...

Page 23: ...ection inhibition is required You can also set the whole rolling shutter travel 2 Press the programming push button four times 3 The motor performs three brief movements to confirm you have entered th...

Page 24: ...lete the position previously stored in the memory 2 The motor performs a brief movement in both directions to confirm the performed deletion If you want to set a new preferred position perform the pro...

Page 25: ...FROM THE REMOTE CONTROL Remote control not memory stored Memory store the first remote control A NEW REMOTE CONTROL CANNOT BE ADDED The maximum number of remote controls that can be memory stored has...

Page 26: ...lux com AUSTRALIA FAAC AUSTRALIA PTY LTD Homebush Sydney Australia tel 61 2 87565644 www faac com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FA...

Reviews: