ENABLE / DISABLE THE SUN SENSOR
(TM2 X SW)
To enable (automatically) or disable (manually) the sun sensor refer to the
instruction manual provided with the sensor or the remote control you want
to use.
TEST MODE FOR TM2 X SW
This function is useful to check the correct communication via radio, and perform
the wind and sun function test.
To activate the TEST function, hold the SET button down for around 2 seconds,
until the awning opens for 10 seconds and closes briefly to confirm that the test
mode is activated. The Test function lasts for 3 minutes, during which the wind
and light level settings can be checked, without waiting for the activation times.
After 3 minutes, the TM2 X SW sensor returns to normal mode function. During
the wind-alarm the red led inside the control unit is on.
WIND FUNCTION TEST
To avoid errors during the wind function test, it is suggested that the sunlight fun-
ction be deactivated. By spinning the anemometer fins, when the speed detected
by the sensor exceeds the threshold set, the motor will close completely the awning.
SUN FUNCTION TEST
Make sure that the sunlight function is on. When the sensor detects a change in the
sunlight intensity, it opens the awning if brighter than the set point or closes it if
weaker. This test can be repeated several times to establish the desired automatic
opening and closing level according to the light.